We experienced two cases of atypical lateral dislocations of meniscal bearing in UKA (unicompartmental knee arthroplasty) without manifest symptoms. The dislocated bearing, which jumped onto the wall of tibial components, was found on radiographs in periodic medical examination although they could walk. Two thicker size bearing exchanges were promptly performed before metallosis and loosening of components. Continual examination is important to mobile bearing type of UKA because slight or less symptoms may disclose such unique dislocation. One case showed malrotation of the femoral component on 3D image. Anteroposterior view hardly disclosed the malrotation of the femoral component. Epicondylar view is an indispensable view of importance, and it can demonstrate the rotation of the femoral component. The the femoral distal end is wedge shaped and is wider posteriorly. If the femoral component is set according to the shape of medial condyle, the femoral component shifts to medial site compared with tibial component in flexion. It can account for such rare dislocation as follows. If excessive force applies on most medial side of the bearing during flexion, the lateral part of the bearing pops and the force squeezes it laterally simultaneously. Finally, the bearing jumps onto the lateral wall of the tibial component.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4475566 | PMC |
http://dx.doi.org/10.1155/2015/217842 | DOI Listing |
J Arthroplasty
January 2025
Stryker, Mahwah, NJ, USA. Electronic address:
Background: The ideal anteversion at which the acetabular and femoral components for a total hip arthroplasty (THA) should be implanted is still a subject of debate. One alignment philosophy being explored is restoration of individual constitutional femoral and acetabular anteversion. This study aimed to measure combined anteversion in a healthy hip population and understand the expected phenotypes and ranges for constitutional hip alignment.
View Article and Find Full Text PDFACS Biomater Sci Eng
January 2025
Department of Mechanical Engineering, Cleveland State University, Cleveland, Ohio 44115, United States.
Polyetheretherketone (PEEK) is a high-performance polymer material for developing varying orthopedic, spine, cranial, maxillofacial, and dental implants. Despite their commendable mechanical properties and biocompatibility, the major limitation of PEEK implants is their low affinity to osseointegrate with the neighboring bone. Over the last two decades, several efforts have been made to incorporate bioactive components such as bioceramic particles in PEEK to enhance its osseointegration capacity.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
January 2025
Clinical Research Department, Sydney Knee Specialists, Kogarah, New South Wales, Australia.
Purpose: In functionally aligned (FA) total knee arthroplasty (TKA), femoral component rotation (FCR) is personalised to optimise flexion gap balance. As axial malalignment has been attributed to patellofemoral complications, this study assessed FA FCR in relation to the surgical transepicondylar axis (TEA) and early implant survivorship.
Methods: We analysed 446 robotic-assisted primary TKAs in 393 patients using FA with preresection gap balancing.
Cureus
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.
Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, People's Republic of China.
Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.
Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!