Objective: The objective of this study was to optically verify the dynamic behaviors of adherent microbubbles in large blood vessel environments in response to a new ultrasound technique using modulated acoustic radiation force.
Materials And Methods: Polydimethylsiloxane (PDMS) flow channels coated with streptavidin were used in targeted groups to mimic large blood vessels. The custom-modulated acoustic radiation force beam sequence was programmed on a Verasonics research scanner. In vitro experiments were performed by injecting a biotinylated lipid-perfluorobutane microbubble dispersion through flow channels. The dynamic response of adherent microbubbles was detected acoustically and simultaneously visualized using a video camera connected to a microscope. In vivo verification was performed in a large abdominal blood vessel of a murine model for inflammation with injection of biotinylated microbubbles conjugated with P-selectin antibody.
Results: Aggregates of adherent microbubbles were observed optically under the influence of acoustic radiation force. Large microbubble aggregates were observed solely in control groups without targeted adhesion. Additionally, the dispersion of microbubble aggregates were demonstrated to lead to a transient acoustic signal enhancement in control groups (a new phenomenon we refer to as "control peak"). In agreement with in vitro results, the control peak phenomenon was observed in vivo in a murine model.
Conclusions: This study provides the first optical observation of microbubble-binding dynamics in large blood vessel environments with application of a modulated acoustic radiation force beam sequence. With targeted adhesion, secondary radiation forces were unable to produce large aggregates of adherent microbubbles. Additionally, the new phenomenon called control peak was observed both in vitro and in vivo in a murine model for the first time. The findings in this study provide us with a better understanding of microbubble behaviors in large blood vessel environments with application of acoustic radiation force and could potentially guide future beam sequence designs or signal processing routines for enhanced ultrasound molecular imaging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4598275 | PMC |
http://dx.doi.org/10.1097/RLI.0000000000000185 | DOI Listing |
J Acoust Soc Am
January 2025
Grundfos A/S, Bjerringbro, 8550, Denmark.
In this paper, an improved version of the classical equivalent radiated power (ERP) approximation is proposed based on principled physical arguments. A geometry-, frequency-, and vibration pattern-dependent approximation of radiation efficiency is developed and used as a corrective factor for the classical ERP approximation. The proposed method called "radiation efficiency varying equivalent radiated power" (revERP), is shown to greatly improve the accuracy of classical ERP at low Helmholtz numbers, while attaining the accuracy of classical ERP at high Helmholtz numbers.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Key Laboratory of Testing Technology for Manufacturing Process MOE, Southwest University of Science and Technology, Mianyang 621010, China.
The directivity of the quasi-static component (QSC) is quantitatively investigated for evaluating the orientation of a micro-crack buried in a thin solid plate using the numerical simulation method. Based on the bilinear stress-strain constitutive model, a three-dimensional (3D) finite element model (FEM) is built for investigating the nonlinear interaction between primary Lamb waves and the micro-crack. When the primary Lamb waves at A0 mode impinge on the micro-crack, under the modulation of the contact acoustic nonlinearity (CAN), the micro-crack itself will induce QSC.
View Article and Find Full Text PDFSensors (Basel)
January 2025
State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum, Beijing 102249, China.
Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.
View Article and Find Full Text PDFOtol Neurotol
February 2025
Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.
Background Introduction: Vestibular schwannoma (VS) tumors typically present with sensorineural hearing loss (SNHL). Losartan has recently demonstrated prevention of tumor-associated SNHL in a mouse model of VS through suppression of inflammatory and pro-fibrotic factors, and the current study investigates this association in humans.
Methods: This is a retrospective study of patients with unilateral VS and hypertension followed with sequential audiometry at a tertiary referral hospital from January 1994 to June 2023.
Adv Sci (Weinh)
January 2025
CNRS, Univ. Bordeaux, CRPP, UMR 5031, Pessac, F-33600, France.
Three-dimensional multicellular aggregates (MCAs) like organoids and spheroids have become essential tools to study the biological mechanisms involved in the progression of diseases. In cancer research, they are now widely used as in vitro models for drug testing. However, their analysis still relies on tedious manual procedures, which hinders their routine use in large-scale biological assays.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!