A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Double Transducer for High Precision Ultrasonic Time-Domain Reflectometry Measurements. | LitMetric

A Double Transducer for High Precision Ultrasonic Time-Domain Reflectometry Measurements.

Sensors (Basel)

Laboratory of Physics, School of Engineering Science, Lappeenranta University of Technology, P.O. Box 20, Lappeenranta FIN-53851, Finland.

Published: June 2015

Membrane fouling, where unwanted particles accumulate on the membrane surface and reduce its permeability, causes problems in membrane filtration processes. With ultrasonic time-domain reflectometry (UTDR) it is possible to measure the extent of membrane fouling and hence take actions to minimize it. However, the usability of UTDR is very limited to constant filtration conditions if the sonic velocity, which has a great impact on UTDR measurement accuracy, is unknown. With a reference transducer the actual sonic velocity can be measured. This requires another transducer to be installed in the module, where there may be only limited space or the module dimensions may not be suitable for the reference transducer. A double transducer described in this study eliminates the need for a separate reference transducer because in the double transducer the reference measurement is included in the design of the transducer holder. Two sensors in the same holder require less space. Other advantage is that the double transducer can be placed near the measurement target and hence the local sonic velocity can be determined.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541822PMC
http://dx.doi.org/10.3390/s150715090DOI Listing

Publication Analysis

Top Keywords

double transducer
16
sonic velocity
12
reference transducer
12
ultrasonic time-domain
8
time-domain reflectometry
8
membrane fouling
8
transducer
8
transducer double
8
double
4
transducer high
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!