We present a simple and highly sensitive cantilever-enhanced photo-acoustic sensor for detection of nitrogen dioxide. A noise equivalent detection limit of 50 parts-per-trillion in 1 s is demonstrated. The limit was reached with an average optical power of 4.7 W using a continuous-wave laser at 532 nm. The achieved normalized noise equivalent absorption coefficient was 2.6×10(-10)  W cm(-1) Hz(-1/2).

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.40.002933DOI Listing