Low-dispersion laser ablation (LA) has been combined with inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to provide full-spectrum elemental imaging at high lateral resolution and fast image-acquisition speeds. The low-dispersion LA cell reported here is capable of delivering 99% of the total LA signal within 9 ms, and the prototype TOFMS instrument enables simultaneous and representative determination of all elemental ions from these fast-transient ablation events. This fast ablated-aerosol transport eliminates the effects of pulse-to-pulse mixing at laser-pulse repetition rates up to 100 Hz. Additionally, by boosting the instantaneous concentration of LA aerosol into the ICP with the use of a low-dispersion ablation cell, signal-to-noise (S/N) ratios, and thus limits of detection (LODs), are improved for all measured isotopes; the lowest LODs are in the single digit parts per million for single-shot LA signal from a 10-μm diameter laser spot. Significantly, high-sensitivity, multielemental and single-shot-resolved detection enables the use of small LA spot sizes to improve lateral resolution and the development of single-shot quantitative imaging, while also maintaining fast image-acquisition speeds. Here, we demonstrate simultaneous elemental imaging of major and minor constituents in an Opalinus clay-rock sample at a 1.5 μm laser-spot diameter and quantitative imaging of a multidomain Pallasite meteorite at a 10 μm LA-spot size.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.5b01196 | DOI Listing |
Environ Sci Technol
December 2024
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
Dust released from widely established plastic sports courts and synthetic turf poses potential environmental and health risks. Herein, we systematically investigate the metal(loid) characteristics, potential sources, and health risks of 162 dust samples from 17 campuses in Beijing, using complementary analytical techniques. Bulk analysis revealed higher levels of Zn, Pb, Cu, Sb, Cd, and Cr than background values, suggesting excessive anthropogenic contamination.
View Article and Find Full Text PDFAnal Chem
December 2024
Department of Chemistry, Iowa State University, Ames, Iowa 50011-2140, United States.
Additive manufacturing or 3D printing is rapidly growing in popularity. This growth brings increased interest in studying the byproducts released during 3D printing. In this work, we present a new method to collect and analyze the metal composition of individual particles released during the operation of fused deposition modeling (FDM) 3D printers using single-particle inductively coupled plasma time-of-flight mass spectrometry (spICP-TOFMS).
View Article and Find Full Text PDFJ Anal At Spectrom
January 2025
ETH Zurich, Department of Chemistry and Applied Biosciences Vladimir-Prelog-Weg 1 8093 Zurich Switzerland
A fundamental study of four different sample introduction systems was carried out to evaluate the upper size limit of microplastics measured by inductively coupled plasma-time-of-flight-mass spectrometry (ICP-TOFMS). Three different, certified microplastic samples (PS, PMMA and PVC) within a size range of 3-20 µm in suspension were measured. In this study, no particles larger than 10 µm could be detected using pneumatic nebulization for sample introduction.
View Article and Find Full Text PDFAnal Chim Acta
December 2024
Institute of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Strasse 38, 1090, Vienna, Austria. Electronic address:
Background: Bioimaging applications by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) require comprehensive elemental analysis spanning the entire mass range. Within biological systems, endogenous elements are critical for maintaining metal homeostasis in cells, a fundamental aspect in disease progression when disrupted. Additionally, elements from the higher mass range may originate from various sources such as metal-tags for immuno-mass spectrometry, nanoparticles, or metal-based anticancer drugs.
View Article and Find Full Text PDFBioact Mater
January 2025
Joint Department of Biomedical Engineering, Medical College of Wisconsin, Marquette University, USA.