Purpose: To compare the diagnostic accuracy of prone (18)F-FDG PET/CT with that of contrast-enhanced MRI (CE-MRI) at 3 T in suspicious breast lesions. To evaluate the influence of tumour size on diagnostic accuracy and the use of maximum standardized uptake value (SUVMAX) thresholds to differentiate malignant from benign breast lesions.

Methods: A total of 172 consecutive patients with an imaging abnormality were included in this IRB-approved prospective study. All patients underwent (18)F-FDG PET/CT and CE-MRI of the breast at 3 T in the prone position. Two reader teams independently evaluated the likelihood of malignancy as determined by (18)F-FDG PET/CT and CE-MRI independently. (18)F-FDG PET/CT data were qualitatively evaluated by visual interpretation. Quantitative assessment was performed by calculation of SUVMAX. Sensitivity, specificity, diagnostic accuracy, area under the curve and interreader agreement were calculated for all lesions and for lesions <10 mm. Histopathology was used as the standard of reference.

Results: There were 132 malignant and 40 benign lesions; 23 lesions (13.4%) were <10 mm. Both (18)F-FDG PET/CT and CE-MRI achieved an overall diagnostic accuracy of 93%. There were no significant differences in sensitivity (p = 0.125), specificity (p = 0.344) or diagnostic accuracy (p = 1). For lesions <10 mm, diagnostic accuracy deteriorated to 91% with both (18)F-FDG PET/CT and CE-MRI. Although no significant difference was found for lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than (18)F-FDG PET/CT. Interreader agreement was excellent (κ = 0.85 and κ = 0.92). SUVMAX threshold was not helpful in differentiating benign from malignant lesions.

Conclusion: (18)F-FDG PET/CT and CE-MRI at 3 T showed equal diagnostic accuracies in breast cancer diagnosis. For lesions <10 mm, diagnostic accuracy deteriorated, but was equal for (18)F-FDG PET/CT and CE-MRI at 3 T. For lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than (18)F-FDG PET/CT. Quantitative assessment using an SUVMAX threshold for differentiating benign from malignant lesions was not helpful in breast cancer diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-015-3099-1DOI Listing

Publication Analysis

Top Keywords

18f-fdg pet/ct
20
diagnostic accuracy
16
contrast-enhanced mri
8
pet/ct ce-mri
8
18f-fdg
5
pet/ct
5
diagnostic
4
accuracy 18f-fdg
4
pet/ct compared
4
compared contrast-enhanced
4

Similar Publications

Phosphaturic mesenchymal tumor (PMT) is a rare benign mesenchymal tumor characterized by excessive secretion of fibroblast growth factor 23 (FGF23), leading to phosphate loss and systemic osteomalacia. Despite recent progress in PMT research, no consensus on diagnosis and treatment guidelines has been established. This case series describes the clinical and pathological features of six pathologically confirmed PMT patients treated at the Third Affiliated Hospital of Sun Yat-sen University from 2010 to 2024, aiming to provide new insights for the management of this condition.

View Article and Find Full Text PDF

To establish and validate a nomogram based on clinical characteristics and metabolic parameters derived from F-fluorodeoxyglucose positron emission tomography and computed tomography (F-FDG PET/CT) for prediction of high-grade patterns (HGP) in invasive lung adenocarcinoma. The clinical and PET/CT image data of 311 patients who were confirmed invasive lung adenocarcinoma and underwent pre-treatment F-FDG PET/CT scan in Beijing Hospital between October 2017 and March 2022 were retrospectively collected. The enrolled patients were divided into HGP group (196 patients) and non-HGP group (115 patients) according to the presence and absence of HGP.

View Article and Find Full Text PDF

Purpose: There are attempts to assess tumor heterogeneity by texture analysis. However, the ordered subsets-expectation maximization (OSEM) reconstruction method has problems depicting heterogeneities. The aim of this study was to identify image reconstruction parameters that improve the ability to depict internal tumor necrosis using a self-made phantom that simulates internal necrosis.

View Article and Find Full Text PDF

multilocular thymic cysts are uncommon acquired cysts in the anterior mediastinum caused by incomplete thymic involution. They may be associated with autoimmune diseases, such as rheumatoid arthritis and systemic sclerosis. a 61-year-old man with a history of rheumatoid arthritis for 8 years was referred to our unit because of a multiloculated mass in the anterior mediastinum with a high F fluorodeoxyglucose uptake at PET-CT scan.

View Article and Find Full Text PDF

Prostate cancer (PCa) is a high-prevalence disease usually characterized by metastatic spread to the pelvic lymph nodes and bones and the development of visceral metastases only in the late stages of disease. Positron Emission Tomography (PET) plays a key role in the detection of PCa metastases. Several PET radiotracers are used in PCa patients according to the stage and pathological features of the disease, in particular Ga/F-prostate-specific membrane antigen (PSMA) ligands.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!