The ability to stabilize the gun is crucial for performance in Olympic pistol shooting and is thought to be related to the shooters muscular strength. The present study examines the relation between performance and finger flexor force as well as shoulder abduction isometric force in senior male air pistol shooting. 46 Spanish national level shooters served as test subjects of the study. Two maximal force tests were carried out recording handgrip and deltoid force data under competition conditions, during the official training time at national Spanish championships. Performance was measured as the total score of 60 shots at competition. Linear regressions were calculated to examine the relations between performance and peak and average finger flexor forces, peak and average finger flexor forces relative to the BMI, peak and average shoulder abduction isometric forces, peak shoulder abduction isometric force relative to the BMI. The connection between performance and other variables such as age, weight, height, BMI, experience in years and training hours per week was also analyzed. Significant correlations were found between performance at competition and average and peak finger flexor forces. For the rest of the force variables no significant correlations were found. Significant correlations were also found between performance at competition and experience as well as training hours. No significant correlations were found between performance and age, weight, height or BMI. The study concludes that hand grip strength training programs are necessary for performance in air pistol shooting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4486452PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0129862PLOS

Publication Analysis

Top Keywords

finger flexor
20
air pistol
12
pistol shooting
12
shoulder abduction
12
abduction isometric
12
peak average
12
flexor forces
12
correlations performance
12
performance
10
flexor force
8

Similar Publications

Ultrasound-guided trigger thumb release.

Hand Surg Rehabil

January 2025

CHU de Nîmes, avenue du Pr Debré, 30000 Nîmes, France.

The purpose of this study was to evaluate the results of a novel retrograde ultrasound-guided A1 pulley release technique for the treatment of trigger thumb. We conducted a retrospective, single-center study of 42 patients who underwent ultrasound-guided A1 pulley release for clinically diagnosed trigger thumb between September 2022 and December 2023. All cases were graded according to the Green classification of trigger finger severity.

View Article and Find Full Text PDF

Synovial osteochondromatosis is a relatively rare condition of the hand. We present a rare case of a locked finger in a paediatric patient with synovial osteochondromatosis, in which a tumourous lesion was continuous with the flexor tendon and trapped proximal to the A1 pulley. After resection of the tumour and synovium, no recurrence was observed over a 6-month follow-up period.

View Article and Find Full Text PDF

Anatomical Characterization of the Motor Branch to the Fourth Lumbrical: A Cadaver Study.

J Hand Surg Am

January 2025

Division of Plastic and Reconstructive Surgery, Department of Surgery, University of Florida, Gainesville, FL.

Purpose: The branching pattern of the deep motor branch of the ulnar nerve (DBUN) in the hand is complex. The anatomy of the motor branch innervating the fourth lumbrical (4L), where paralysis results in a claw hand deformity after ulnar nerve injury, is not well defined. This cadaver study focused on mapping and defining anatomical landmarks in relation to the motor branch to the 4L.

View Article and Find Full Text PDF

Ultrasound-guided trigger finger release with a minimally invasive knife: A retrospective analysis of 297 releases.

Hand Surg Rehabil

January 2025

Chirurgie de la Main et de la Membre supérieur, Médipôle 1 rue Jules Méline, 51430 Bezannes, France.

Trigger finger, or stenosing tenovaginitis, is a common condition characterized by impaired flexor tendon sliding due to thickening of the A1 pulley. While open surgical release remains the gold standard for the treatment of persistent trigger finger, there is increasing interest in minimally invasive ultrasound-guided techniques to improve precision and outcomes. The purpose of this study is to evaluate the outcomes, safety, and complications associated with ultrasound-guided trigger finger release using a minimally invasive surgical knife.

View Article and Find Full Text PDF

Diffuse-type giant cell tumor of the tendon sheath (GCTTS) is a rare, benign, yet locally aggressive soft tissue tumor commonly affecting the hand. This case report presents a 55-year-old male with a 5-year history of GCTTS in the flexor tendon sheath of the long finger. MRI played a critical role in both diagnosis and surgical planning, revealing key features such as the tumor's 10 cm length, hemosiderin deposition, and blooming artifacts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!