Purpose: To report results on 144 cases following arthroscopic resection arthroplasty (ARA) with or without interposition for basal joint arthritis.

Methods: Cases undergoing ARA for thumb carpometacarpal osteoarthritis between 2004 and 2011 were prospectively enrolled (n = 178). Data were collected before surgery and after surgery at 1, 3, 6, and 12 months and annually thereafter. Patients were excluded for less than 1-year follow-up or concomitant procedures that interfered with evaluation of the variable of interest (interposition). Human acellular dermal matrix (GRAFTJACKET) was the most commonly used interposition. Outcomes on 19 cases of interposition using collagen bioimplant (OrthADAPT) and porous polyurethaneurea (Artelon) scaffolds were also reported. Comparative analyses were performed on 52 patients with GRAFTJACKET interposition and on 73 without. Mean follow-up was 7.4 and 5.6 years with and without interposition, respectively. Descriptive statistics were evaluated on all baseline variables. Raw change scores of grip, pinch, and pain outcomes were evaluated. Confounding variables at a significance level of P less than .05 were adjusted for in linear mixed models, and an analysis of covariance was employed through an unstructured type of variance-covariance matrix.

Results: Change scores from baseline to 1 year for the interposition group for pain (numerical rating scale, 0-10), pinch, and grip was -5.8, 3.3, and 7, respectively, and -5.1, 2.1, and 9 for the noninterposition group. Postoperative mean satisfaction was 4.7 and 4.4 for the with- and without-interposition groups, respectively. There were 4 failures with and 2 without interposition. Artelon and OrthADAPT did poorly with unacceptably high failure rates.

Conclusions: This study suggested that interposition is not necessary following ARA for thumb basal joint arthritis. Because arthroscopic interposition of material contributes to health care costs in terms of patient and facility costs without clear benefit to the patient, routine use of expensive interposition products should be abandoned or carefully evaluated with a prospective randomized controlled trial.

Type Of Study/level Of Evidence: Therapeutic IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2015.05.010DOI Listing

Publication Analysis

Top Keywords

interposition
12
basal joint
12
arthroscopic resection
8
resection arthroplasty
8
thumb basal
8
joint arthritis
8
ara thumb
8
change scores
8
long-term outcome
4
outcome arthroscopic
4

Similar Publications

Development of a Wearable Electromyographic Sensor with Aerosol Jet Printing Technology.

Bioengineering (Basel)

December 2024

Movement Control and Neuroplasticity Research Group, KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium.

Electromyographic (EMG) sensors are essential tools for analyzing muscle activity, but traditional designs often face challenges such as motion artifacts, signal variability, and limited wearability. This study introduces a novel EMG sensor fabricated using Aerosol Jet Printing (AJP) technology that addresses these limitations with a focus on precision, flexibility, and stability. The innovative sensor design minimizes air interposition at the skin-electrode interface, thereby reducing variability and improving signal quality.

View Article and Find Full Text PDF

Para-Anastomotic Pseudoaneurysms as a Long-Term Complication After Surgical Treatment of Peripheral Artery Disease: Clinical Characteristics and Surgical Treatment.

Biomedicines

November 2024

Department of General Surgery, Vascular Surgery, Angiology and Phlebology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 45-47 Ziołowa Street, 40-635 Katowice, Poland.

Peripheral arterial disease (PAD) is becoming an increasingly prevalent clinical issue, leading to a growing number of patients requiring surgical interventions. Consequently, there is an increasing occurrence of para-anastomotic aneurysms as late complications following primary treatment for PAD. These aneurysms typically arise at the sites of graft implantation and necessitate individualized management strategies based on factors such as location, size, and the patient's overall condition.

View Article and Find Full Text PDF

Objective: Proximal gastrectomy (PG) is commonly used to remove proximal gastric cancer leading to gastroesophageal reflux and requires digestive tract reconstruction. This study is to compare the performance of esophagogastrostomy (EG), jejunal interposition (JI), and double tract reconstruction (DTR) on post-PG reconstruction effectiveness.

Methods: A retrospective study was conducted using the clinical data of 94 PG patients who underwent digestive tract reconstruction by EG (37 patients), JI (29 patients) or DTR (28 patients).

View Article and Find Full Text PDF

Light-curing of restorative composite through milled and 3D-printed full-contour zirconia for adhesive luting.

Dent Mater

January 2025

KU Leuven, Department of Oral Health Sciences, BIOMAT & UZ Leuven, Dentistry, Kapucijnenvoer 7, 3000 Leuven, Belgium. Electronic address:

Objectives: To evaluate the effect of different zirconia compositions and manufacturing processes on the light irradiance (LI), to measure the degree of conversion (DC) of solely light-curing restorative composite underneath these zirconia grades and to evaluate the respective zirconia microstructures.

Methods: Six dental zirconia grades (GC HT, GC UHT [GC]; Katana HT, Katana UTML [Kuraray Noritake]; Lava Esthetic, Lava Plus [3 M Oral Care]) were cut and sintered per manufacturer instructions. One 3D-printed zirconia grade (XJet [XJET]) was prepared according to previous research.

View Article and Find Full Text PDF

Surgical options and outcomes for treatment of osteoarthritis of the scaphotrapeziotrapezoidal joint.

J Hand Surg Eur Vol

January 2025

Institut de la main Nantes-Atlantique, Saint-Herblain, France.

Osteoarthritis of the scaphotrapeziotrapezoidal joint is frequent but often pain-free or well tolerated with non-surgical treatment. Surgical options are numerous and none seems to have clear evidence of superiority. In addition to well-established procedures, such as scaphotrapeziotrapezoidal joint arthrodesis, distal scaphoid resection and trapeziectomy, more recent surgical techniques have been reported.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!