Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: This study sought to compare the effect of paclitaxel-coated balloon (PCB) concentration on tissue levels and vascular healing using 3 different PCB technologies (In.Pact Pacific = 3 μg/mm(2), Lutonix = 2 μg/mm(2) and Ranger = 2 μg/mm(2)) in the experimental setting.
Background: The optimal therapeutic dose for PCB use has not been determined yet.
Methods: Paclitaxel tissue levels were measured up to 60 days following PCB inflation (Ranger and In.Pact Pacific) in the superficial femoral artery of healthy swine (18 swine, 36 vessels). The familial hypercholesterolemic swine model of superficial femoral artery in-stent restenosis (6 swine, 24 vessels) was used in the efficacy study. Two weeks following bare-metal stent implantation, each in-stent restenosis site was randomly treated with a PCB or an uncoated control balloon (Sterling). Quantitative vascular analysis and histology evaluation was performed 28 days following PCB treatment.
Results: All PCB technologies displayed comparable paclitaxel tissue levels 4 h following balloon inflation. At 28 days, all PCB had achieved therapeutic tissue levels; however, the In.Pact PCB resulted in higher tissue concentrations than did the other PCB groups at all time points. Neointimal inhibition by histology was decreased in all PCB groups compared with the control group, with a greater decrease in the In.Pact group. However, the neointima was more mature and contained less peri-strut fibrin deposits in both 2-μg/mm(2) PCB groups.
Conclusions: Compared with the clinically established PCB dose, lower-dose PCB technologies achieve lower long-term tissue levels but comparable degrees of neointimal inhibition and fewer fibrin deposits. The impact of these findings in restenosis reduction and clinical outcomes needs to be further investigated.