Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To validate the Labor and Delivery Index (LADY-X), a new delivery-specific utility measure.
Study Design And Setting: In a test-retest design, women were surveyed online, 6 to 8 weeks postpartum and again 1 to 2 weeks later. For reliability testing, we assessed the standard error of measurement (S.E.M.) and the intraclass correlation coefficient (ICC). For construct validity, we tested hypotheses on the association with comparison instruments (Mackey Childbirth Satisfaction Rating Scale and Wijma Delivery Experience Questionnaire), both on domain and total score levels. We assessed known-group differences using eight obstetrical indicators: method and place of birth, induction, transfer, control over pain medication, complications concerning mother and child, and experienced control.
Results: The questionnaire was completed by 308 women, 257 (83%) completed the retest. The distribution of LADY-X scores was skewed. The reliability was good, as the ICC exceeded 0.80 and the S.E.M. was 0.76. Requirements for good construct validity were fulfilled: all hypotheses for convergent and divergent validity were confirmed, and six of eight hypotheses for known-group differences were confirmed as all differences were statistically significant (P-values: <0.001-0.023), but for two tests, difference scores did not exceed the S.E.M.
Conclusion: The LADY-X demonstrates good reliability and construct validity. Despite its skewed distribution, the LADY-X can discriminate between groups. With the preference weights available, the LADY-X might fulfill the need for a utility measure for cost-effectiveness studies for perinatal care interventions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jclinepi.2015.05.020 | DOI Listing |