A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomimetic modification of silicone tubes using sodium nitrite-collagen immobilization accelerates endothelialization. | LitMetric

Biomimetic modification of silicone tubes using sodium nitrite-collagen immobilization accelerates endothelialization.

J Biomed Mater Res B Appl Biomater

Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam, University of Amsterdam and VU University Amsterdam, MOVE Research Institute Amsterdam, Amsterdam, The Netherlands.

Published: October 2016

Biomimetic coatings to increase endothelialization of blood-contacting materials in biomedical devices are promising to improve the biocompatibility of these devices. Although a stable extracellular matrix protein coating on a biomaterial's surface is a prerequisite for endothelial cell attachment, it also stimulates platelet adhesion. Therefore, antithrombotic additives, such as nitric oxide donors, to a stable protein coating might lead to successful endothelialization of a material's surface. We aimed to test whether immobilized bioactive nitrite and acidified nitrite-generating sodium nitrite-collagen conjugate on silicone tubes enhances endothelialization by increasing the number of endothelial cells as well as growth hormone production and by decreasing platelet adhesion. Stable collagen immobilization on acrylic acid-grafted silicone tubes decreased the water contact angle from 102° to 56°. Initial 25 µM sodium nitrite in conjugate resulted in maximal growth hormone production (2.5-fold increase) and endothelial cell number (1.8-fold increase) after 2 days. A 95% confluent endothelial cell monolayer on sodium nitrite-collagen conjugate coating was obtained after 6 days. Maximum (2.7-fold) inhibition of platelet adhesion was reached with initial 500 µM sodium nitrite in conjugate. Our data showing that sodium nitrite-collagen conjugate coating with 25-50 µM sodium nitrite on silicone tubes increases the number of endothelial cells attached and inhibits platelet adhesion suggest that this coating is highly promising for use in blood-contacting parts of biomedical devices. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1311-1321, 2016.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.33412DOI Listing

Publication Analysis

Top Keywords

silicone tubes
16
sodium nitrite-collagen
16
platelet adhesion
16
endothelial cell
12
nitrite-collagen conjugate
12
µm sodium
12
sodium nitrite
12
biomedical devices
8
protein coating
8
number endothelial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!