Immediate postpartum insertion of intrauterine device for contraception.

Cochrane Database Syst Rev

Clinical and Epidemiological Sciences, FHI 360, 359 Blackwell St, Suite 200, Durham, North Carolina, USA, 27701.

Published: June 2015

Background: Women who want to start intrauterine contraception (IUC) during the postpartum period might benefit from IUC insertion immediately after delivery. Postplacental insertion greatly reduces the risk of subsequent pregnancy and eliminates the need for a return visit to start contraception. Without the option of immediate insertion, many women may never return for services or may adopt less effective contraception.

Objectives: Our aim was to examine the outcomes of IUC insertion immediately after placenta delivery (within 10 minutes), especially when compared with insertion at other postpartum times. We focused on successful IUC placement (insertion), subsequent expulsion, and method use.

Search Methods: We searched for trials until 1 April 2015. Sources included PubMed (MEDLINE), the Cochrane Central Register of Controlled Trials (CENTRAL), POPLINE, Web of Science, EMBASE, LILACS, ClinicalTrials.gov, and ICTRP. For the original review, the authors contacted investigators to identify other trials.

Selection Criteria: We sought randomized controlled trials (RCTs) with at least one treatment arm that involved immediate IUC placement (i.e., within 10 minutes of placenta delivery). Comparison arms could have included early postpartum insertion (from 10 minutes postplacental to hospital discharge) or standard insertion (during a postpartum visit). Trials could also have compared different IUC methods or insertion techniques. Delivery may have been vaginal or cesarean. Primary outcomes were placement (insertion), subsequent expulsion, and method use at study assessment.

Data Collection And Analysis: For dichotomous outcomes, we used the Mantel-Haenszel odds ratio (OR) with 95% confidence interval (CI). Earlier studies primarily reported results as life-table rates. We aggregated trials in a meta-analysis if they had similar interventions and outcome measures. A sensitivity analysis included studies with moderate or high quality evidence and sufficient outcome data.

Main Results: We included 15 trials. Seven studies reported from 2010 to 2014 were added to eight from the original 2001 review. Newer trials compared immediate postplacental insertion versus early (10 minutes to 48 hours) or standard insertion (during the postpartum visit). Of four with full reports, three were small trials. The other three studies had conference abstracts. The eight early trials examined immediate insertion of different devices or insertion techniques. Most studies were published in the 1980s, some with limited reporting.Our sensitivity analysis included trials with sufficient outcome data and moderate or high quality evidence. Four newer trials comparing insertion times met the inclusion criteria. Two studies used the levonorgestrel-releasing intrauterine system (LNG-IUS) after vaginal delivery. The other two trials placed IUC after cesarean section; one used the CuT 380A intrauterine device (IUD) and the other used the LNG-IUS.A pilot trial compared immediate insertion versus early or standard insertion. In groups comparing immediate versus early insertion (N = 30), all women had the LNG-IUS inserted. By six months, the groups had the same expulsion rate and did not differ significantly in IUC use.For immediate versus standard insertion, we conducted meta-analyses of four trials. Insertion rates did not differ significantly between study arms. However, the trial from Uganda showed insertion was more likely for the immediate group, although the estimate was imprecise. In the meta-analysis, expulsion by six months was more likely for the immediate group, but the confidence interval was wide (OR 4.89, 95% CI 1.47 to 16.32; participants = 210; studies = 4). IUC use at six months was more likely with immediate insertion than with standard insertion (OR 2.04, 95% CI 1.01 to 4.09; participants = 243; studies = 4). Study arms did not differ in use at 3 or 12 months in individual small trials.

Authors' Conclusions: Recent trials compared different insertion times after vaginal or cesarean delivery. Evidence was limited because studies with full reports generally had small sample sizes. Overall, the quality of evidence was moderate; abstracts and older studies had limited reporting. Ongoing trials will add to the evidence, although some are small. Trials of adequate power are needed to estimate expulsion rates and side effects.The benefit of effective contraception immediately after delivery may outweigh the disadvantage of increased risk for expulsion. Frequent prenatal visits during the third trimester provide the opportunity to discuss effective contraceptive methods and desired timing for initiation. Clinical follow-up can help detect early expulsion, as can educating women about expulsion signs and symptoms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10777269PMC
http://dx.doi.org/10.1002/14651858.CD003036.pub3DOI Listing

Publication Analysis

Top Keywords

insertion
24
standard insertion
20
trials
16
compared insertion
12
insertion postpartum
12
trials compared
12
quality evidence
12
versus early
12
studies
10
iuc
9

Similar Publications

The evolution of radiation therapy in Uganda has been a journey marked by significant milestones and persistent challenges. Since the inception of radiotherapy services in 1988-1989, there has been a concerted effort to enhance cancer treatment services. The early years were characterized by foundational developments, such as the installation of the first teletherapy units, low-dose-rate brachytherapy units, and conventional simulators, and the recognition of radiation oncologists and medical physicist professionals laid the groundwork for radiotherapy treatment modalities.

View Article and Find Full Text PDF

Errors are robustly tamed in cumulative knowledge processes.

Proc Natl Acad Sci U S A

February 2025

Computer Science, School of Engineering and Applied Sciences, Harvard University, Boston, MA 02134.

As knowledge accumulates in science and society in a distributed fashion, erroneous derivations can be introduced into the corpus of knowledge. Such derivations can compromise the validity of any units of knowledge that rely on them in the future. Can societal knowledge maintain some level of integrity given simple distributed error-checking mechanisms? In this paper, we investigate the following formulation of the question: assuming that a constant fraction of the new derivations is wrong, is it possible for simple error-checking mechanisms that apply when a new unit of knowledge is derived to maintain the integrity of the corpus of knowledge? This question was introduced by Ben-Eliezer et al.

View Article and Find Full Text PDF

Case: A 30-year-old man presented with left proximal tibia fracture (open Grade 3A) and a transverse lateral malleolus fracture (Weber B) following direct impact injury. Computed tomography revealed a rare posteromedial tubercle fibula fracture at the posterior inferior tibiofibular ligament (PITFL) insertion, with syndesmosis disruption. Initial damage control included an external fixator.

View Article and Find Full Text PDF

We lack tools to edit DNA sequences at scales necessary to study 99% of the human genome that is noncoding. To address this gap, we applied CRISPR prime editing to insert recombination handles into repetitive sequences, up to 1697 per cell line, which enables generating large-scale deletions, inversions, translocations, and circular DNA. Recombinase induction produced more than 100 stochastic megabase-sized rearrangements in each cell.

View Article and Find Full Text PDF

Pre-established anaesthetic protocols in animal models might unexpectedly interfere with the main outcome of scientific projects and therefore they need to account for the specific research goals. We aimed to optimize the anaesthetic protocol and animal handling strategies in a diabetes-related-study exemplifying how the anaesthetic approach must be adjusted for individual research targets. Aachen minipigs were used as a model to test long-lasting skin glucose sensors for diabetic human patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!