Internal exposure to uranium in a pooled cohort of gaseous diffusion plant workers.

Radiat Prot Dosimetry

Division of Surveillance, Hazard Evaluations and Field Studies (DSHEFS), National Institute for Occupational Safety and Health (NIOSH), 1090 Tusculum Ave., MS R-14., Cincinnati, OH 45226, USA.

Published: March 2016

Intakes and absorbed organ doses were estimated for 29 303 workers employed at three former US gaseous diffusion plants as part of a study of cause-specific mortality and cancer incidence in uranium enrichment workers. Uranium urinalysis data (>600 000 urine samples) were available for 58 % of the pooled cohort. Facility records provided uranium gravimetric and radioactivity concentration data and allowed estimation of enrichment levels of uranium to which workers may have been exposed. Urine data were generally recorded with facility department numbers, which were also available in study subjects' work histories. Bioassay data were imputed for study subjects with no recorded sample results (33 % of pooled cohort) by assigning department average urine uranium concentration. Gravimetric data were converted to 24-h uranium activity excretion using department average specific activities. Intakes and organ doses were calculated assuming chronic exposure by inhalation to a 5-µm activity median aerodynamic diameter aerosol of soluble uranium. Median intakes varied between 0.31 and 0.74 Bq d(-1) for the three facilities. Median organ doses for the three facilities varied between 0.019 and 0.051, 0.68 and 1.8, 0.078 and 0.22, 0.28 and 0.74, and 0.094 and 0.25 mGy for lung, bone surface, red bone marrow, kidneys, and liver, respectively. Estimated intakes and organ doses for study subjects with imputed bioassay data were similar in magnitude.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4690811PMC
http://dx.doi.org/10.1093/rpd/ncv357DOI Listing

Publication Analysis

Top Keywords

organ doses
16
pooled cohort
12
uranium
8
gaseous diffusion
8
bioassay data
8
study subjects
8
department average
8
intakes organ
8
three facilities
8
data
6

Similar Publications

Automatic segmentation of cardiac structures can change the way we evaluate dose limits for radiotherapy in the left breast.

J Med Imaging Radiat Sci

December 2024

Department of Radiotherapy, Instituto Brasileiro de Controle do Câncer (IBCC), Avenida Alcântara Machado, 2576, Mooca, 03102-002 São Paulo, SP, Brazil; Department of Radiotherapy, Instituto de Radiologia do Hospital das Clínicas - HCFMUSP (InRad), Hospital das Clínicas, University of São Paulo, Rua Doutor Ovídio Pires de Campos, 75, Portaria 1, Cerqueira César, 05403-010 São Paulo, SP, Brazil.

Purpose: Radiotherapy is a crucial part of breast cancer treatment. Precision in dose assessment is essential to minimize side effects. Traditionally, anatomical structures are delineated manually, a time-consuming process subject to variability.

View Article and Find Full Text PDF

The application of pesticides may adversely impact a variety of non-target organisms. The use of side-effect-free herbal remedies to protect against the toxicity of harmful pesticides such as etoxazole has gained attention in recent times. The current study aimed to reveal the potential mitigating efficacy of Achillea millefolium L.

View Article and Find Full Text PDF

Evaluation of diflubenzuron-verapamil combination strategy for eco-safe management of .

Front Physiol

December 2024

Department of Zoology, Acharya Narendra Dev College, University of Delhi, New Delhi, India.

Introduction: , the vector of multiple arboviral diseases, is a prime health concern worldwide. The surge in borne diseases emphasizes the urgent need for efficient vector control measures. Synthetic pesticides used traditionally, however, present environmental concerns and issues like resistance development, causing the use of higher chemical doses.

View Article and Find Full Text PDF

Background: Acute kidney injury (AKI) requiring continuous renal replacement therapy is common in critically ill patients. The ADVanced Organ Support (ADVOS) system is a novel hemodialysis machine that uses albumin enriched dialysate which allows the removal of protein-bound toxins and drugs. To date, data on antimicrobial removal under ADVOS has not yet been reported.

View Article and Find Full Text PDF

Background: Stress can cause an increase in proinflammatory cytokines, IL-6, which plays a role in the inflammatory response and causes changes in the placenta, causing a low risk of the fetus being born. Giving nanocurcumin, which functions as an anti-inflammatory and antioxidant, is expected to reduce cortisol levels which increase during pregnancy.

Aim: This study aims to determine the effect of stress during pregnancy on pregnant mice, namely IL-6 expression and fetal body weight.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!