This paper presents a novel strategy for the prevention of ventilator-associated pneumonia that involves coating poly(vinyl chloride, PVC) endotracheal tubes (ET) with hydrogels that may be subsequently used to entrap nebulized antimicrobial solutions. Candidate hydrogels were prepared containing a range of ratios of hydroxyethyl methacrylate (HEMA) and methacrylic acid (MAA) from 100:0 to 70:30 using free radical polymerization and, when required, simultaneous attachment to PVC was performed. The mechanical properties, glass transition temperatures, swelling kinetics, uptake of gentamicin from an aqueous medium, and gentamicin release were characterized. Increasing the MAA content of the hydrogels significantly decreased the ultimate tensile strength, % elongation at break, Young's modulus, and increased the glass transition temperature, the swelling ratio, and gentamicin uptake. Microbial (Staphylococcus aureus and Pseudomonas aeruginosa) adherence to control (drug-free) hydrogels was observed; however, while adherence to gentamicin-containing p(HEMA) occurred, no adherence occurred to gentamicin-containing HEMA:MAA copolymers. Antimicrobial persistence of gentamicin-containing hydrogels was examined by determining the zone of inhibition against each microorganism on successive days. Hydrogel composition affected the observed antimicrobial persistence, with the hydrogel composed of 70:30 HEMA:MAA exhibiting >20 days persistence against S. aureus and P. aeruginosa, respectively. To simulate clinical use, the hydrogels (coated onto PVC) were first exposed to a nebulized solution of gentamicin (4 mL, 80 mg for 20 min), and then to nebulized bacteria (4 mL ca. 1×10(9) colony forming units mL(-1), 30 min). Viable bacteria were not observed on the gentamicin-treated p(HEMA: MAA) copolymers, whereas growth was observed on gentamicin-treated p(HEMA). In light of the excellent antimicrobial activity and physicochemical properties, p(HEMA: MAA) copolymers composed of ratios of 80:20 or 70:30 HEMA: MAA were identified as potentially useful coatings of endotracheal tubes to be used in conjunction with the clinical nebulization of gentamicin and designed for the prevention of ventilator-associated pneumonia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.molpharmaceut.5b00208 | DOI Listing |
Indian J Crit Care Med
December 2024
Department of Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Background: Development of ventilator-associated pneumonia (VAP) is attributed to the microaspiration of pooled secretions around the cuff of airway devices. Despite the emphasis on the use of endotracheal tubes (ET) with subglottic secretion (SS) drainage ports to prevent VAP, the quality of the evidence for this recommendation remains moderate. This prospective observational study analyzed microbiological concordance between SS and endotracheal aspirate (ETA) cultures to generate further evidence in this regard.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Anesthesiology, Kafkas University Medical Faculty, Kars, Turkey.
Abstarct: BACKGROUND: The optimal positioned double-lumen endotracheal tubes (DLT) is crucial in thoracic surgery requiring lung isolation. This study aims to compare the accuracy and complication rates of DLT placement using videolaryngoscopy (VL) versus conventional direct laryngoscopy (DL).
Methods: This retrospective single-center study included 89 patients who underwent thoracic surgery with DLT placement between July 2023 and May 2024.
Cureus
December 2024
Department of Pediatrics, Sapporo Medical University School of Medicine, Sapporo, JPN.
Lip ulcers associated with endotracheal tube fixation are a known complication in adults, but their prevalence in neonates and preterm infants remains unclear. We report a case of a right oral commissure ulcer that developed during endotracheal tube fixation at the right oral commissure and left lateral decubitus positioning in an extremely preterm infant with unilateral pulmonary interstitial emphysema (PIE). A male infant was born at 24 weeks and four days of gestation, weighing 696 gm.
View Article and Find Full Text PDFActa Med Port
January 2025
Introduction: Healthcare-associated infections are an important cause of morbidity and mortality in the pediatric population and a growing problem in intensive care services. However, limited data are available on these infections in the Portuguese pediatric population. This study aimed to estimate its prevalence rate in a Portuguese pediatric intensive care unit, identifying the most frequent microorganisms and their antibiotic resistance profiles.
View Article and Find Full Text PDFJ West Afr Coll Surg
August 2024
Department of Anaesthesia, University of Nigeria Teaching Hospital, Ituku-Ozalla, Enugu, Nigeria.
Background: Considerable morbidity is attributable to inappropriate tracheal cuff pressure. An earlier study undertaken in our hospital revealed that a normal cuff pressure of 20-30 cm HO was achieved in only 6% of intubated patients using subjective estimation methods.
Objective: To determine whether a training intervention could improve the accuracy of the subjective estimation method in our tracheal cuff monitoring.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!