A label-free and selective aptamer beacon-based Love-wave biosensing device was developed for prostate specific antigen (PSA) detection. The device consists of the following parts: LiTaO3 substrate with SiO2 film as wave guide layer, two set of inter-digital transducers (IDT), gold film for immobilization of the biorecongniton layer and a polydimethylsiloxane (PDMS) microfluidic channels. DNA aptamer, or "artificial antibody", was used as the specific biorecognition probe for PSA capture. Some nucleotides were added to the 3'-end of the aptamer to form a duplex with the 3'-end, turning the aptamer into an aptamer-beacon. Taking advantage of the selective target-induced assembly changes arising from the "aptamer beacon", highly selective and specific detection of PSA was achieved. Furthermore, PDMS microfluidic channels were designed and fabricated to realize automated quantitative sample injection. After optimization of the experimental conditions, the established device showed good performance for PSA detection between 10 ng/mL to 1 μg/mL, with a detection limit of 10 ng/mL. The proposed sensor might be a promising alternative for point of care diagnostics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4507688PMC
http://dx.doi.org/10.3390/s150613839DOI Listing

Publication Analysis

Top Keywords

psa detection
12
love-wave biosensing
8
biosensing device
8
pdms microfluidic
8
microfluidic channels
8
psa
5
detection
5
aptamer
5
microfluidic love-wave
4
device
4

Similar Publications

Unconventional Imaging Methods in Psoriatic Arthritis.

Curr Rheumatol Rep

January 2025

Department of Rheumatology and Clinical Immunology, Charité - Universitätsmedizin Berlin, Berlin, Germany.

Purpose Of Review: Psoriatic arthritis (PsA) is a complex heterogeneous inflammatory disease that affects about one-third of patients with psoriasis. PsA leads to significant physical impairment and reduced quality of life. Therefore, early diagnosis and intervention are critical for improving long-term outcomes.

View Article and Find Full Text PDF

Prostate cancer antigen 3 (PCA3) has emerged as a critical biomarker for the early detection of prostate cancer, complementing the traditional prostate-specific antigen (PSA) testing. This research presents a novel resistive sensor based on reduced graphene oxide (RGO) functionalized with glutaraldehyde (GA)/complementary single-stranded DNA (ss-DNA) for the detection of the PCA3 RNA. The device was meticulously characterized at each fabrication step to confirm the successful integration of the various layers on the sensor device, utilizing atomic force microscopy (AFM) which confirmed the increase in the thickness of the sensor from ∼1.

View Article and Find Full Text PDF

Background and objective Prostate cancer (PCA) is the most prevalent cancer among males. The National Institute for Health and Care Excellence (NICE) recommends referral to PCA diagnostic pathway based on two criteria: (1) abnormal digital rectal examination (DRE) and (2) elevated prostate-specific antigen (PSA). This study evaluates the diagnostic value of routine DRE in patients undergoing PCA assessment with pre-biopsy MRI.

View Article and Find Full Text PDF

Objective: To identify clinicopathologic and genomic features associated with brain metastasis after resection of lung adenocarcinoma (LUAD) and to evaluate survival after brain metastasis.

Methods: Patients who underwent complete resection of stage I-IIIA LUAD between 2011 and 2020 were included. A subset of patients had broad-based panel next-generation sequencing performed on their tumors.

View Article and Find Full Text PDF

Characterized by their high sensitivity and flexible deformation, flexible pressure sensors have been extensively applied in various fields such as wearable electronics, health monitoring, soft robotics, and human-computer interaction. In this research, we developed a dual-response pressure sensor (DRPS) designed to identify object materials. By integrating the operating principles of capacitive and resistive sensors and employing microstructured dielectric layers, we enhanced the sensitivity and detection range of the pressure sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!