Purpose: Capsular tension rings (CTRs) are commonly used for stabilizing the capsule in lax zonules. Blind and uncontrolled maneuvering of the ring free end may cause intraoperative incidents during CTR insertion. We improved the design of a standard CTR typical injector that eliminates the risks associated with the lack of control during its insertion.
Methods: We present a modification of a typical injector used for insertion of standard CTR as well as the insertion technique. The modification consists of a metal anchoring element attached to the free end of the tube, on which the second eyelet of a standard CTR is fixed. The device was used in the surgical treatment of 50 adult patients with cataract associated with lax zonule.
Results: The improved injector led to a reduced injection duration and complexity, and there were no intraoperative incidents or postoperative complications.
Conclusions: The fixation of the second eyelet allows a controlled insertion of the standard CTRs, which facilitates the intraocular implantation technique, reduces surgical complications associated with the blind maneuvering of the free end of the ring inserted by traditional methods, and has a less disruptive action on the integrity of the remaining undamaged zonular fibers in the lax zonules. The accessory attached to the typical injector tube reduces the risk of surgical incidents caused by the uncontrolled progression of the ring's free end inside the capsular bag.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5301/ejo.5000613 | DOI Listing |
J Robot Surg
January 2025
Department of Pediatric Anesthesia and Intensive Care, Necker-Enfants Malades University Hospital, AP-HP Centre, Université Paris Cité, 149, Rue de Sèvres 75015, Paris, France.
Retroperitoneal robotic-assisted laparoscopic pyeloplasty (R-RALP) is the commonest urologic procedure performed in children, entailing retroperitoneal CO2 insufflation and lateral decubitus, whose effects on cardiopulmonary variables are poorly known. We, therefore, studied hemodynamic and respiratory changes due to CO2 insufflation and lateral decubitus in children undergoing R-RALP and their effects on regional tissue oxygenation. Between 1/2021 and 7/2024, children affected by ureteropelvic joint obstruction (UPJO) underwent a pyeloplasty by R-RALP at Necker Enfants Malades Hospital (Paris, France), using a standardized surgical technique and a lung-protecting anesthetic protocol aimed to prevent hypercarbia.
View Article and Find Full Text PDFAnn Clin Microbiol Antimicrob
January 2025
Department of Clinical Laboratory, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, 410008, Hunan, China.
Background: The emergence of colistin resistance in carbapenem-resistant Klebsiella pneumoniae (CRKP) is a significant public health concern, as colistin has been the last resort for treating such infections. This study aimed to investigate the prevalence and molecular characteristics of colistin-resistant CRKP isolates in Central South China.
Methods: CRKP isolates from twelve hospitals in Central South China were screened for colistin resistance using broth microdilution.
Ann Otol Rhinol Laryngol
January 2025
Department of Otolaryngology-Head and Neck Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
Objectives: The primary objective of this case series is to assess the effectiveness of the off-label use of the PROPEL drug-eluting stent, traditionally FDA-approved for sinus surgery, in preventing restenosis following canalplasty in patients with chronic otologic conditions or congenital anomalies. The stent provides both mechanical support to maintain canal patency and localized steroid delivery to reduce inflammation and scarring.
Methods: Four patients with various otologic conditions underwent canalplasty, followed by the placement of drug-eluting stents into the external auditory canal.
Int J Artif Organs
January 2025
Konya Şehir Hastanesi, Konya, Turkey.
Background: Bleeding and thrombotic occlusion are complications of Central venous catheters. When selecting a catheter lock solution, factors such as bleeding, thrombotic occlusion, infection, and cost-effectiveness must be considered.
Methods: The study included 35 patients who used heparin as a locking solution and 35 patients who used 0.
J Med Syst
January 2025
Department of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.