Diagnostic accuracy of heart murmur in newborns with suspected congenital heart disease.

J Cardiovasc Med (Hagerstown)

aDepartment of Medical and Surgical Sciences, University of Foggia, Foggia bDivision of Neonatology, Department of Paediatrics, University Hospital A. Gemelli, Catholic University of Sacred Heart, Rome, Italy.

Published: August 2015

Background: The correlation between heart murmur and congenital heart disease (CHD) is complex and varies with observed population.

Methods: Ninety consecutive newborns (41 with heart murmur and 49 controls) were routinely examined with auscultation and echocardiography. Intensity and characteristics of heart murmur, presence and type of CHD were recorded. Echocardiographic findings were considered as benchmark.

Results: Heart murmur was related to the presence of ostium secundum [odds ratio (OR) 4.2], patent ductus arteriosus (OR 11.9), tricuspidal regurgitation (OR 9.5), muscle ventricular septal defect (VSD) (OR 12.3), membranous VSD (OR 9.7), and any CHD (OR 26.7) (P < 0.05 in all cases). Diagnostic accuracy of clinical examination with a finding of heart murmur was 83%, lower if considering single CHD (58-69%), negative predictive value 90%, and positive predictive value 76%. Patients with any CHD, tricuspidal regurgitation and muscle VSD were characterized by a more intense heart murmur. In case of concomitant multiple CHD, intensity of heart murmur correlated with the number of congenital heart anomalies.

Conclusion: Diagnostic accuracy of heart murmur at clinical examination (83%) declines when single CHDs are considered. Higher negative predictive value and lower positive predictive value suggest an echocardiographic second-level confirmation in the case of heart murmur at clinical examination suspected for CHD, probably unnecessary in the case of negative auscultative findings. Heart murmur intensity correlates with the number of concomitant congenital heart anomalies.

Download full-text PDF

Source
http://dx.doi.org/10.2459/JCM.0b013e3283649953DOI Listing

Publication Analysis

Top Keywords

heart murmur
20
congenital heart
8
heart disease
8
murmur presence
8
heart
7
murmur
5
diagnostic accuracy
4
accuracy heart
4
murmur newborns
4
newborns suspected
4

Similar Publications

Noise Reduction in Abdominal Acoustic Recordings of Maternal Placental Murmurs.

Biomed Phys Eng Express

January 2025

Department of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, Aalborg, 9260, DENMARK.

Unlabelled: Fetal phonocardiography is a well-known auscultation technique for evaluation of fetal health. However, murmurs that are synchronous with the maternal heartbeat can often be heard while listening to fetal heart sounds. Maternal placental murmurs (MPM) could be used to detect maternal cardiovascular and placental abnormalities, but the recorded MPMs are often contaminated by ambient interference and noise.

View Article and Find Full Text PDF

Background: 22q11 deletion syndrome consists of a variable grouping of phenotypic features and immunological defects secondary to the loss of genetic material located in the 22q11.2 band. The 22q11 deletion spectrum encompasses different syndromes related to the same etiology and with overlapping anomalies, including DiGeorge syndrome, velocardiofacial syndrome, among others.

View Article and Find Full Text PDF

Echocardiographic Changes in Dogs with Stage B2 Myxomatous Mitral Valve Disease Treated with Pimobendan Monotherapy.

Vet Sci

November 2024

Department of Small Animal Clinical Science, School of Veterinary Science, University of Liverpool, Cardiology Service, Small Animal Teaching Hospital, Chester High Road, Neston CH64 7TE, UK.

The present study aimed to evaluate the effects of chronic pimobendan monotherapy on cardiac size in dogs with stage B2 myxomatous mitral valve disease (MMVD). Data from 31 dogs diagnosed with MMVD and cardiomegaly (LA/Ao ≥ 1.6 and LVIDdn ≥ 1.

View Article and Find Full Text PDF

Background: Subclinical leaflet thrombosis (SLT) is a common complication after transcatheter aortic valve replacement (TAVR). Multidimensional CT (MDCT) is the main imaging mortality for the diagnosis of SLT but it enhances the risk of contrast-induced nephropathy. Our study aimed to use an innovative wearable acoustic cardiography (ACG) device to diagnose SLT as an alternative option.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!