A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Plume Characteristics of Two HFA-Driven Inhaled Corticosteroid/Long-Acting Beta2-Agonist Combination Pressurized Metered-Dose Inhalers. | LitMetric

Plume Characteristics of Two HFA-Driven Inhaled Corticosteroid/Long-Acting Beta2-Agonist Combination Pressurized Metered-Dose Inhalers.

Adv Ther

Mundipharma Research Ltd, Unit 191, Cambridge Science Park, Milton Road, Cambridge, CB4 0GW, UK,

Published: June 2015

Introduction: New inhalers propelled by hydrofluoroalkanes (HFAs) have improved plume characteristics: higher fine particle fraction, and warmer plumes with reduced force and velocity. Together, this may avoid reflex interruption of inhalation and improve lung deposition of the inhaled drugs. However, even with HFA-propelled pressurized metered-dose inhalers (pMDIs), there are notable differences in device properties. Here we compared the duration, velocity, force, and temperature of two inhaled corticosteroid/long-acting β2-agonist combination therapies, administered via HFA pMDIs: fluticasone propionate/formoterol 125/5 µg (FP/FORM; flutiform(®)) and fluticasone propionate/salmeterol 125/25 µg (FP/SAL; Seretide(®) Evohaler(®)).

Methods: Inhalers were fired into ambient air. Plume duration and velocity were recorded with a high-speed camera and a pulsed laser light source. A copper disc attached to a sensitive load cell measured the plume force at various distances from the device. A thermal imaging video camera recorded impaction temperature in line with the device.

Results: The average plume duration for FP/FORM was longer than that of FP/SAL: 168.3 vs. 114.0 ms, respectively. The mean maximum plume velocities observed at 95 mm (the approximate distance between mouthpiece and throat) was consistently slower for FP/FORM (10.08 m/s) compared to FP/SAL (15.55 m/s). FP/FORM had a slower velocity at the outset, remaining relatively constant before declining steadily over the plume duration. The force of the FP/SAL plume was greater than that of FP/FORM at all distances: maximum force for FP/FORM was 138.2 vs. 278.9 mN for FP/SAL. The minimum impaction temperature was +5.9 °C for FP/FORM and -37.8 °C for FP/SAL; this difference became less pronounced over distance.

Conclusion: There were substantial differences between the plumes of the two pMDIs. FP/FORM was warmer, less forceful, had a longer plume duration and slower maximal velocity. These plume characteristics of FP/FORM may lead to improved lung deposition.

Funding: Mundipharma Research Limited, Cambridge, UK.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12325-015-0219-zDOI Listing

Publication Analysis

Top Keywords

plume duration
16
plume characteristics
12
plume
10
fp/form
9
inhaled corticosteroid/long-acting
8
pressurized metered-dose
8
metered-dose inhalers
8
duration velocity
8
impaction temperature
8
fp/sal
6