Purpose: Processing stereoscopic image data is an emerging field. Especially in microsurgery that requires sub-millimeter accuracy, application of stereo-based methods on endoscopic and microscopic scenarios is of major interest. In this context, direct comparison of stereo-based surface reconstruction applied to several camera settings is presented.
Methods: A method for stereo matching is proposed and validated on in-vitro data. Demonstrating suitability for surgical scenarios, this method is applied to two custom-made stereo cameras, a miniaturized, bendable surgical endoscope and an operating microscope. Reconstruction accuracy is assessed on a custom-made reference sample. Subsequent to its fabrication, a coordinate measuring arm is used to acquire ground truth. Next, the sample is positioned by a robot at varying distances to each camera. Surface estimation is performed, while the specimen is localized based on. markers. Finally, the error between estimated surface and ground truth is computed.
Results: Sample measurement with the coordinate measuring arm yields reliable ground truth data with a root-mean-square error of 11.2 μm. Overall surface reconstruction with analyzed cameras is quantified by a root-mean-square error of less than 0.18 mm. Microscope setting with the highest magnification yields the most accurate measurement, while the maximum deviation does not exceed 0.5 mm. Custom-made stereo cameras perform similar but with outliers of increased magnitude. Miniaturized, bendable surgical endoscope produces the maximum error of approximately 1.2 mm.
Conclusions: Reconstruction results reveal that microscopic imaging outperforms investigated chip-on-the-tip solutions, i.e., at higher magnification. Nonetheless, custom-made cameras are suitable for application in microsurgery. Although reconstruction with the miniaturized endoscope is more inaccurate, it provides a good trade-off between accuracy, outer dimensions and accessibility to hard-to-reach surgical sites.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11548-015-1240-z | DOI Listing |
Inorg Chem
January 2025
Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Eco-functional Polymer Materials of the Ministry of Education, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070, Gansu, China.
Efficient and stable nonprecious metal-based oxygen evolution reaction (OER) electrocatalysts are pivotal for water electrolysis technology. Herein, we are reporting an effective strategy for fabricating efficient Co-based OER electrocatalysts by low-level Fe doping in CoMoO to boost surface reconstruction and electronic modulation, which resulted in excellent OER electroactivity consequently. Our findings reveal that a mere 5.
View Article and Find Full Text PDFFront Plant Sci
January 2025
Cluster of Excellence "Understanding Written Artefacts", University of Hamburg, Hamburg, Germany.
We studied freshly collected, dried and herbarized leaf fragments of two palms, namely L. and L., most commonly used for palm-leaf manuscript (PLM) production in South (S) and Southeast Asia (SE) in order to reveal differences in their phytolith assemblages.
View Article and Find Full Text PDFChemistryOpen
January 2025
Facultad de Ciencias Básicas, Universidad de Medellín, 050026, Medellín, Colombia.
Conversion of glycerol to added-value products is desirable due to its surplus during biodiesel synthesis. TiO has been the most explored catalyst. We performed a systematic study of glycerol adsorption on anatase (101), anatase (001), and rutile (110) TiO at the Density Functional Theory level.
View Article and Find Full Text PDFIn the realm of 3D measurement, photometric stereo excels in capturing high-frequency details but suffers from accumulated errors that lead to low-frequency distortions in the reconstructed surface. Conversely, light field (LF) reconstruction provides satisfactory low-frequency geometry but sacrifices spatial resolution, impacting high-frequency detail quality. To tackle these challenges, we propose a photometric stereoscopic light field measurement (PSLFM) scheme that harnesses the strengths of both methods.
View Article and Find Full Text PDFThe significant absorption and scattering of light during its propagation in water severely degrade the quality of underwater imaging, presenting challenges for developing high-precision 3D imaging techniques based on optical methods. Polarization imaging has demonstrated effectiveness in mitigating the effects of scattering, making it a valuable approach for underwater imaging. Additionally, the polarization state of reflected light can be utilized for surface normal estimation and 3D shape reconstruction.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!