Fast simultaneous LC/MS/MS determination of 10 active compounds in human serum for therapeutic drug monitoring in psychiatric medication.

Biomed Chromatogr

Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 779 00, Olomouc, Czech Republic.

Published: February 2016

A UPLC/MS/MS method with simple protein precipitation has been validated for the fast simultaneous analysis of agomelatine, asenapine, amisulpride, iloperidone, zotepine, melperone, ziprasidone, vilazodone, aripiprazole and its metabolite dehydro-aripiprazole in human serum. Alprenolol was applied as an internal standard. A BEH C18 (2.1 × 50 mm, 1.7 µm) column provided chromatographic separation of analytes using a binary mobile phase gradient (A, 2 mmol/L ammonium acetate, 0.1% formic acid in 5% acetonitrile, v/v/v; B, 2 mmol/L ammonium acetate, 0.1% formic acid in 95% acetonitrile, v/v/v). Mass spectrometric detection was performed in the positive electrospray ionization mode and ion suppression owing to matrix effects was evaluated. The validation criteria were determined: linearity, precision, accuracy, recovery, limit of detection, limit of quantification, reproducibility and matrix effect. The concentration range was as follows: 0.25-1000 ng/mL for agomelatine; 0.25-100 ng/mL for asenapine and iloperidone; 2.5-1000 ng/mL for amisulpride, aripiprazole, vilazodone and zotepine; 2.3-924.6 ng/mL for dehydroaripiprazole; 2.2-878.4 ng/mL for melperone; and 2.2-883.5 ng/mL for ziprasidone. Limits of quantitation below a therapeutic reference range were achieved for all analytes. Intra-run precision of 0.4-5.5 %, inter-run precision of 0.6-8.2% and overall recovery of 87.9-114.1% were obtained. The validated method was successfully implemented into routine practice for therapeutic drug monitoring in our hospital.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.3538DOI Listing

Publication Analysis

Top Keywords

fast simultaneous
8
human serum
8
therapeutic drug
8
drug monitoring
8
mmol/l ammonium
8
ammonium acetate
8
acetate 01%
8
01% formic
8
formic acid
8
acetonitrile v/v/v
8

Similar Publications

Vascular cognitive impairment and dementia (VCID), resulting from chronic cerebral hypoperfusion, represent the second most prevalent form of dementia globally. Aerobic exercise is widely acknowledged as an effective intervention for various cognitive disorders. This study utilized a bilateral common carotid artery stenosis (BCAS) model to investigate whether aerobic exercise promotes cognitive recovery through the Annexin-A1 (ANXA1)/mitogen-activated protein kinase (MAPK) axis in BCAS mice.

View Article and Find Full Text PDF

Stacked meshes with super-wettability atmospheric plasma for efficient emulsion separation.

Nanoscale

January 2025

CAS Key Laboratory of Bio-inspired Materials and Interface Sciences, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

Common filter membranes for emulsion separation often require time-intensive preparation and extensive use of chemicals, necessitating a fast-processing and eco-friendly alternative. This study introduces a 2-layer stacked nylon mesh treated with surface diffuse atmospheric plasma (SDAP) for rapid and efficient emulsion separation. Commercial nylon mesh exhibited durable super-wetting properties after just 30 s of SDAP treatment, which was sufficient for effective emulsion separation.

View Article and Find Full Text PDF

This paper introduces a novel unsupervised inverse-consistent diffeomorphic registration network termed IConDiffNet, which incorporates an energy constraint that minimizes the total energy expended during the deformation process. The IConDiffNet architecture consists of two symmetric paths, each employing multiple recursive cascaded updating blocks (neural networks) to handle different virtual time steps parameterizing the path from the initial undeformed image to the final deformation. These blocks estimate velocities corresponding to specific time steps, generating a series of smooth time-dependent velocity vector fields.

View Article and Find Full Text PDF

Extraction of compression indices from maternal-fetal heart rate simultaneous signals.

PLoS One

January 2025

MEDCIDS - Department of Community Medicine, Information and Decision in Health, Faculty of Medicine, University of Porto, Porto, Portugal.

Intrapartum asphyxia is responsible for approximately 900 000 deaths per year worldwide. These numbers show the urgency of investing in the quality of fetal health care. The heart rate signal is a complex signal and sometimes behaves unpredictably.

View Article and Find Full Text PDF

Fast ramp fraction loss SVM classifier with low computational complexity for pattern classification.

Neural Netw

December 2024

College of Life Science, Hunan Normal University, Changsha, PR China. Electronic address:

The support vector machine (SVM) is a powerful tool for pattern classification thanks to its outstanding efficiency. However, when encountering extensive classification tasks, the considerable computational complexity may present a substantial barrier. To reduce computational complexity, the novel ramp fraction loss SVM model called L-SVM is introduced.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!