Purpose: The purpose of this study was to verify clinical target volume--planning target volume (CTV-PTV) margins in single vocal cord irradiation (SVCI) of T1a larynx tumors and characterize inter- and intrafraction target motion.
Methods And Materials: For 42 patients, a single vocal cord was irradiated using intensity modulated radiation therapy at a total dose of 58.1 Gy (16 fractions × 3.63 Gy). A daily cone beam computed tomography (CBCT) scan was performed to online correct the setup of the thyroid cartilage after patient positioning with in-room lasers (interfraction motion correction). To monitor intrafraction motion, CBCT scans were also acquired just after patient repositioning and after dose delivery. A mixed online-offline setup correction protocol ("O2 protocol") was designed to compensate for both inter- and intrafraction motion.
Results: Observed interfraction, systematic (Σ), and random (σ) setup errors in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions were 0.9, 2.0, and 1.1 mm and 1.0, 1.6, and 1.0 mm, respectively. After correction of these errors, the following intrafraction movements derived from the CBCT acquired after dose delivery were: Σ = 0.4, 1.3, and 0.7 mm, and σ = 0.8, 1.4, and 0.8 mm. More than half of the patients showed a systematic non-zero intrafraction shift in target position, (ie, the mean intrafraction displacement over the treatment fractions was statistically significantly different from zero; P<.05). With the applied CTV-PTV margins (for most patients 3, 5, and 3 mm in LR, CC, and AP directions, respectively), the minimum CTV dose, estimated from the target displacements observed in the last CBCT, was at least 94% of the prescribed dose for all patients and more than 98% for most patients (37 of 42). The proposed O2 protocol could effectively reduce the systematic intrafraction errors observed after dose delivery to almost zero (Σ = 0.1, 0.2, 0.2 mm).
Conclusions: With adequate image guidance and CTV-PTV margins in LR, CC, and AP directions of 3, 5, and 3 mm, respectively, excellent target coverage in SVCI could be ensured.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijrobp.2015.04.049 | DOI Listing |
Beijing Da Xue Xue Bao Yi Xue Ban
December 2024
Department Of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China.
Objective: To evaluate the intra-fraction and inter-fraction positional deviations in head and neck tumor patients undergoing intensity-modulated radiation therapy (IMRT) guided by cone-beam CT (CBCT), as well as the correction capability and stability of the HexaPOD evo RT 6D couch in addressing these deviations.
Methods: From May 2019 to April 2022, 59 consecutive patients with head and neck tumors were enrolled at the Department of Radiation Oncology, Peking University Third Hospital.Using the Elekta AXESSE image-guided stereotactic treatment system, a pre-treatment CBCT scan was performed, followed by bone window mode registration with the planning reference images.
Phys Med Biol
December 2024
Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
Inter- and intra-fractional anatomical changes during a radiotherapy treatment can cause differences between the initially planned dose and the delivered dose. The total delivered dose can be accumulated over all fractions by using deformable image registration (DIR). However, there is uncertainty in this process which should be accounted for.
View Article and Find Full Text PDFPhys Med Biol
December 2024
Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT).We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach.
View Article and Find Full Text PDFTech Innov Patient Support Radiat Oncol
December 2024
Applied Radiation Therapy Trinity (ARTT), Discipline of Radiation Therapy, School of Medicine, Trinity St. James's Cancer Institute, Trinity College Dublin, University of Dublin, Dublin, Ireland.
Background: Prostate bed (PB) motion may lead to geographical miss of the target volume in post-prostatectomy radiotherapy (RT). Optimal clinical target volume (CTV) to planning target volume (PTV) margins prevent geographical miss and unnecessary irradiation of normal tissue. There is little data available informing appropriate CTV to PTV margins in the post-prostatectomy setting.
View Article and Find Full Text PDFClin Transl Radiat Oncol
January 2025
State Key Laboratory of Oncology in South China, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou 510060, PR China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!