Objective: The objective of the analysis was to review the effectiveness of a care process model (CPM) developed to guide management of patients on insulin pump therapy undergoing elective surgical procedures.

Methods: Electronic medical records were reviewed to assess the impact of the CPM on documentation of insulin pump status, glucose monitoring, and safety during the perioperative phase of care. Post-CPM care was compared with management provided before CPM implementation.

Results: We reviewed 45 cases on insulin pump therapy in the pre-CPM cohort and 106 in the post-CPM cohort. Demographic characteristics, categories of surgery, and perioperative times were not significantly different between the 2 groups. Recommended hemoglobin A1c monitoring occurred in 73% of cases in the pre-CPM cohort but improved to 94% in the post-CPM group (P < .01). There was a higher frequency of documentation of the insulin pump during the preoperative, intraoperative, and postanesthesia care unit segments of care in the post- vs pre-CPM periods (all P < .01). The number of cases with intraoperative glucose monitoring increased (57% pre-CPM vs 81% post-CPM; P < .01). Glycemic control was comparable between the 2 CPM periods. Hypoglycemia was rare, with only 3 episodes in the pre-CPM group and 4 in the post-CPM. No adverse events associated with perioperative insulin pump use were observed.

Conclusions: This analysis adds to previous data on use of insulin pump therapy during the perioperative period. Some processes require additional attention, but data continue to indicate that a standardized approach to care can lead to a successful and safe transition of insulin pump therapy throughout the perioperative period.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4667318PMC
http://dx.doi.org/10.1177/1932296815592027DOI Listing

Publication Analysis

Top Keywords

insulin pump
28
pump therapy
16
insulin
8
documentation insulin
8
glucose monitoring
8
pre-cpm cohort
8
therapy perioperative
8
perioperative period
8
care
7
pump
7

Similar Publications

Background: Insulin pumps coupled with continuous glucose monitoring sensors use algorithms to analyze real-time blood glucose levels. This allows for the suspension of insulin administration before hypoglycemic thresholds are reached or for adaptive tuning in hybrid closed-loop systems. This longitudinal retrospective study aims to analyze real-world glycemic outcomes in a pediatric population transitioning to such devices.

View Article and Find Full Text PDF

Introduction: While people with diabetes (PWD)'s experiences with their insulin delivery systems (IDS) are frequently reported in clinical trials, few real-world data exist on the subject. This study aimed to assess the real-world experience and satisfaction with IDS in PWD.

Methods: This cross-sectional survey of PWD treated with tubed or tubeless insulin pumps, hybrid closed loop (HCL) systems, or multiple daily injections (MDI) for at least 3 months ran from 4 to 16 May 2023.

View Article and Find Full Text PDF

Applying auricular magnetic therapy to decrease blood glucose levels and promote the healing of gangrene in diabetes patients: a case report.

J Med Case Rep

December 2024

Beijing Acupuncture and Chinese Herbology, 19 Edgemoor Road, Lutherville-Timonium, MD, 21093, USA.

Background: Magnetic therapy has demonstrated beneficial effects for reducing pain, nausea, neuropathy, and various other health concerns in the human body. To our knowledge, limited research has documented the use of auricular static magnetic therapy as a potential treatment for diabetes. This report presents the first evidence of using magnetic discs placed at acupuncture points on the human ear to decrease blood glucose levels and promote the healing of gangrene in diabetic patients.

View Article and Find Full Text PDF

Background: Older adults with type 1 diabetes are at risk for serious hypoglycemia. Automated insulin delivery can reduce risk but has not been sufficiently evaluated in this population.

Methods: We conducted a multicenter, randomized crossover trial in adults older than or equal to 65 years of age with type 1 diabetes.

View Article and Find Full Text PDF

Addressing Disparities Using Continuous Glucose Monitors and Remote Patient Monitoring for Youth With Type 1 Diabetes.

J Diabetes Sci Technol

December 2024

Division of Pediatric Endocrinology and Diabetes, Department of Pediatrics, Stanford University, Stanford, CA, USA.

Background: Youth with type 1 diabetes (T1D) and public insurance have lower diabetes technology use. This pilot study assessed the feasibility of a program to support continuous glucose monitor (CGM) use with remote patient monitoring (RPM) to improve glycemia for youth with established T1D and public insurance.

Methods: From August 2020 to June 2023, we provided CGM with RPM support via patient portal messaging for youth with established T1D on public insurance with challenges obtaining consistent CGM supplies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!