On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of pre-column dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4488902PMC
http://dx.doi.org/10.1016/j.chroma.2015.05.071DOI Listing

Publication Analysis

Top Keywords

on-column focusing
16
focusing
9
pre-column dispersion
8
volume overload
8
solvent-based focusing
8
column
8
head column
8
tasf effective
8
column temperature
8
isocratic elution
8

Similar Publications

Diabetes is a critical worldwide health problem. Numerous studies have focused on producing recombinant human insulin to address this issue. In this research, the process factors of production of recombinant His-tagged proinsulin in E.

View Article and Find Full Text PDF

Noncovalent Fluorophore Labeling of Proteins by Propidium Iodide in Sodium Dodecyl Sulfate Capillary Gel Electrophoresis.

Anal Chem

July 2024

Translational Glycomics Group, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, Veszprem 8200, Hungary.

Sodium dodecyl sulfate capillary gel electrophoresis is one of the frequently used methods for size-based protein separation in molecular biology laboratories and the biopharmaceutical industry. To increase throughput, quite a few multicapillary electrophoresis systems have been recently developed, but most of them only support fluorescence detection, requiring fluorophore labeling of the sample proteins. To avoid the time-consuming derivatization reaction, we developed an on-column labeling approach utilizing propidium iodide for the first time in SDS-CGE of proteins, a dye only used before for nucleic acid analysis.

View Article and Find Full Text PDF

A simple extraction-free, on-column trace enrichment liquid chromatographic method for the determination of trace levels of bisphenol A (BPA) in bottled water samples has been developed. It was found possible to determine ng/L (ppt) levels of BPA by the direct introduction of 6 mL of sample water to the HPLC column utilising fluorescence detection (Ex = 274 nm, Em = 314 nm). Following the loading of the sample and the chromatographic focusing of the BPA on the analytical column, a simple switch from the aqueous sample to the isocratic chromatographic elution step of 50% acetonitrile/deionised water was undertaken.

View Article and Find Full Text PDF

We investigated the possibility of reducing the effect of precolumn band broadening (PreCBB) by sandwiching the sample between two small plugs of an immiscible liquid. It has been found that in cases of severe PreCBB, improvements in peak efficiency can amount up to 20 times for the early-eluting compounds. For smaller degrees of PreCBB, the gain on the efficiency of early-eluting compounds is smaller (order of 50%), yet it is still significant.

View Article and Find Full Text PDF

Serially coupled column liquid chromatography: An alternative separation tool.

J Chromatogr A

September 2023

School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China. Electronic address:

Despite the rapid development of liquid chromatography (LC) in recent decades, it remains a challenge to achieve the desired chromatographic separation of complex matrices using a single column. Multi-column LC techniques, particularly serially coupled column LC (SCC-LC), have emerged as a promising solution to overcome this challenge. While more attention has been focused on heart-cutting or comprehensive two-dimensional LC, reviews specifically focusing on SCC-LC, which offers advantages in terms of precision and facile instrumentation, are scarce.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!