Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC's active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4 × 4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16 × 16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92 × 0.92 × 3 mm with 1.0 mm pitch. The outer diameter of the detector block is 16.8 × 16.8 mm. Thirty-two such blocks will be arranged in a 4 × 8 array with 1 mm gaps to form a panel detector with detection area around 7 cm × 14 cm in the full-size detector. The flood histogram acquired with Ge-68 source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module's mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, +/-0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4465487 | PMC |
http://dx.doi.org/10.1016/j.nima.2015.04.071 | DOI Listing |
One Health
December 2024
Centre for the Mathematical Modelling of Infectious Diseases (CMMID), London School of Hygiene and Tropical Medicine, London, UK.
Antibiotic use (ABU) in animals is postulated to be a major contributor to selection of antibiotic resistance (ABR) which subsequently causes infections in human populations. However, there are few quantifications of the size of this association. Denmark, as a country with high levels of pig production and strong ABR surveillance data, is an ideal case study for exploring this association.
View Article and Find Full Text PDFRadiol Imaging Cancer
January 2025
From Case Western Reserve University School of Medicine, Cleveland, Ohio (A.M.); University of Pittsburgh School of Medicine, Pittsburgh, Pa (E.C.); and Department of Radiology, University Hospitals, 11000 Euclid Ave, Bolwell B2600, Cleveland, OH 44115 (K.B., N.R., S.H.T.).
Prostate cancer is the second most common malignancy among male individuals in the United States and requires careful imaging approaches because of its varied presentations. This review examines prostate cancer imaging guidelines from leading organizations, including the American College of Radiology, American Urological Association, European Association of Urology, American Society of Clinical Oncology, and National Comprehensive Cancer Network, and serves as a reference highlighting commonalities and divergences in current imaging recommendations across prostate cancer states. We outline these organizations and their methods, focusing on their approaches to panel expertise, guideline development, evidence grading, and revision schedules.
View Article and Find Full Text PDFJ Avian Med Surg
January 2025
Ennetseeklinik für Kleintiere, Exotic Pet Department, 6331 Hünenberg, Zug, Switzerland.
A captive, 1-year-old, male Eurasian goshawk () weighing 0.85 kg and owned by a falconer was presented with a history of acute onset of weakness, dyspnea, diarrhea, and regurgitation of a fresh-thawed pigeon contaminated with acetamiprid, an insecticide used in the raptor enclosure. The raptor had eaten the contaminated pigeon approximately 10-12 hours earlier.
View Article and Find Full Text PDFExpert Rev Proteomics
January 2025
Skolkovo Institute of Science and Technology, Moscow, Russian Federation.
Introduction: Identifying early risks of developing Alzheimer's disease (AD) is a major challenge as the number of patients with AD steadily increases and requires innovative solutions. Current molecular diagnostic modalities, such as cerebrospinal fluid (CSF) testing and positron emission tomography (PET) imaging, exhibit limitations in their applicability for large-scale screening. In recent years, there has been a marked shift toward the development of blood plasma-based diagnostic tests, which offer a more accessible and clinically viable alternative for widespread use.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
December 2024
Department of Radiation Oncology, Stanford University, Stanford, CA, USA.
Purpose: Nanoparticles are highly efficient vectors for ferrying contrast agents across cell membranes, enabling ultra-sensitive in vivo tracking of single cells with positron emission tomography (PET). However, this approach must be fully characterized and understood before it can be reliably implemented for routine applications.
Methods: We developed a Langmuir adsorption model that accurately describes the process of labeling mesoporous silica nanoparticles (MSNP) with Ga.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!