Flexible Control of Safety Margins for Action Based on Environmental Variability.

J Neurosci

School of Engineering and Applied Sciences, and Center for Brain Science, Harvard University, Cambridge, Massachusetts 02138

Published: June 2015

To reduce the risk of slip, grip force (GF) control includes a safety margin above the force level ordinarily sufficient for the expected load force (LF) dynamics. The current view is that this safety margin is based on the expected LF dynamics, amounting to a static safety factor like that often used in engineering design. More efficient control could be achieved, however, if the motor system reduces the safety margin when LF variability is low and increases it when this variability is high. Here we show that this is indeed the case by demonstrating that the human motor system sizes the GF safety margin in proportion to an internal estimate of LF variability to maintain a fixed statistical confidence against slip. In contrast to current models of GF control that neglect the variability of LF dynamics, we demonstrate that GF is threefold more sensitive to the SD than the expected value of LF dynamics, in line with the maintenance of a 3-sigma confidence level. We then show that a computational model of GF control that includes a variability-driven safety margin predicts highly asymmetric GF adaptation between increases versus decreases in load. We find clear experimental evidence for this asymmetry and show that it explains previously reported differences in how rapidly GFs and manipulatory forces adapt. This model further predicts bizarre nonmonotonic shapes for GF learning curves, which are faithfully borne out in our experimental data. Our findings establish a new role for environmental variability in the control of action.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4469737PMC
http://dx.doi.org/10.1523/JNEUROSCI.1883-14.2015DOI Listing

Publication Analysis

Top Keywords

safety margin
20
environmental variability
8
control includes
8
expected dynamics
8
motor system
8
safety
7
variability
6
control
5
margin
5
flexible control
4

Similar Publications

Background: High-resolution brain imaging is crucial in clinical diagnosis and neuroscience, with ultra-high field strength MRI systems ( ) offering significant advantages for imaging neuronal microstructures. However, achieving magnetic field homogeneity is challenging due to engineering faults during the installation of superconducting strip windings and the primary magnet.

Purpose: This study aims to design and optimize active superconducting shim coils for a 7 T animal MRI system, focusing on the impact of safety margin, size, and adjustability of the second-order shim coils on the MRI system's optimization.

View Article and Find Full Text PDF

Epidemiology, diagnosis and treatment of anterior prostate cancer.

Nat Rev Urol

January 2025

Department of Urology, Guy's and St Thomas' NHS Foundation Trust, London, UK.

Anterior prostate cancers (APCs) are a group of impalpable neoplasms located in regions anterior to the urethra, which comprise the transition zone, apical peripheral zone and anterior fibromuscular stroma. These regions are typically undersampled using conventional biopsy schemes, leading to a low detection rate for APC and a high rate of false negatives. Radical prostatectomy series suggest prevalence rates of at least 10-30%, but transperineal systematic biopsy is ideal for diagnosis, particularly where multiparametric MRI is unavailable.

View Article and Find Full Text PDF

The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.

View Article and Find Full Text PDF

Application of a semi-active robotic system for implant placement in atrophic posterior maxilla: a retrospective case series.

J Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University. Electronic address:

Objective: The study aimed to evaluate the accuracy and safety of the semi-active robotic system for implant placement in atrophic posterior maxilla.

Methods: Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!