Objectives: This retrospective clinical study sought to evaluate the survival of immediate implants placed at maxillary and mandibular single-rooted tooth extraction sites and to determine the relationship among implant size, placement site, and implant survival.

Methods: Between January 2010 and June 2011, 85 patients (33 males, 52 females; mean age: 45 years) underwent immediate implant placement after extraction of single-rooted teeth. All implants were restored between 12 and 14 weeks after implant placement. The implant survival and its relationship with implant size and implantation site were evaluated by odds ratios (ORs).

Results: Implants were placed at the following sites: upper central incisor (UCI, n = 35), upper lateral incisor (ULI, n = 27), upper second premolar (U2ndP, n = 36), lower incisor (LI, n = 53), and lower premolar (LP, n = 22). Implants of the following sizes were used: 5 × 10 mm (n = 24), 5 × 8 mm (n = 21), 4.3 × 10 mm (n = 77), 4.3 × 8 mm (n = 36), 3.5 × 10 mm (n = 12), and 3.5 × 8 mm (n = 3). After a mean follow-up time of 47 months, the overall implant survival rate was 96%. Survival rate was highest at the LI site (98.1%) and lowest at the ULI site (92.6%). All of the 5-mm implants survived (100%), as did most of the 4.3 × 10 mm implants (96.1%). Implants of 4.3 × 8 mm and 3.5 × 10 mm were the least successful (91.7%). Mandibular implants had a better survival rate (97.3%) than maxillary implants (94.9%). There was no significant OR of increased survival for any particular implant size or site.

Conclusions: Immediate implant placement in fresh extraction sockets can give predictable clinical outcomes, regardless of the implant size and site of placement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4459117PMC
http://dx.doi.org/10.1016/j.sdentj.2014.11.003DOI Listing

Publication Analysis

Top Keywords

implant size
16
implant survival
12
implant placement
12
survival rate
12
implant
11
implants
10
size site
8
site placement
8
relationship implant
8
survival
7

Similar Publications

Objective: The orthodontic mini-implant (OMI) failure often occurs due to the accumulation of peri-implantitis bacteria surrounding it, which results in a stable, resistant form of absolute skeletal anchorage during orthodontic treatment. Administering doxycycline may be the solution, but long-term side effects result in antibiotic resistance. Roselle flowers (Hibiscus sabdariffa) possess beneficial active phytochemical substances, which may have potential as an OMI peri-implantitis alternative therapy.

View Article and Find Full Text PDF

Millimeter-scale radioluminescent power for electronic sensors.

iScience

January 2025

Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, CA 94720, USA.

The storage and generation of electrical energy at the mm-scale is a core roadblock to realizing many untethered miniature systems, including industrial, environmental, and medically implanted sensors. We describe the potential to address the sensor energy requirement in a two-step process by first converting alpha radiation into light, which can then be translated into electrical power through a photovoltaic harvester circuit protected by a clear sealant. Different phosphorescent and scintillating materials were mixed with the alpha-emitter Th-227, and the conversion efficiency of europium-doped yttrium oxide was the highest at around 2%.

View Article and Find Full Text PDF

Achieving high-crystalline-quality, large-size iron garnet magneto-optic (MO) films on silicon substrates remains a critical challenge for CMOS-compatible on-chip non-reciprocal devices like isolators and circulators. In this study, we explored ion slicing on commercial yttrium iron garnet (YIG) crystals, bismuth-doped iron garnet (BIG), and newly developed YIG ceramics. After He ion implantation, wafer bonding and annealing, the BIG film on silicon was successfully fabricated, but its thickness and crystalline phase deviated from expectations.

View Article and Find Full Text PDF

Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).

Methods: This study was a single-center retrospective cohort study.

View Article and Find Full Text PDF

The design and characterisation of a novel dual-band implantable antenna with compact size is presented in this research. The antenna, which is [Formula: see text] in size and operates at two critical frequencies-0.954 GHz in the UHF band and 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!