Although transcatheter aortic valve implantation (TAVI) is still currently guided by transesophageal echocardiography (TEE) in a considerable number of hospitals, exclusive angiographic (Angio) guidance seems a reasonable approach in this setting. To date, however, no studies have directly compared the outcomes of TAVI according to the imaging modality used for procedural guidance. We, therefore, used data from a large multicenter data repository to compare the outcomes of TAVI guided exclusively by Angio and ATEE. All consecutive patients with severe aortic stenosis who underwent TAVI with the CoreValve Revalving System (CRS) in 9 Italian centers from September 2007 to March 2014, dichotomized according to the imaging support used to guide the procedure (ATEE and Angio), were included. Thirty-day and 12-month clinical outcomes were evaluated. Propensity matching analysis was performed to adjust for baseline differences. A total of 625 patients were included (256 and 369 patients were included in the ATEE and Angio groups, respectively). Patients from the ATEE more frequently underwent TAVI under general anesthesia compared with Angio group (37.9% vs 22.8%, respectively, p <0.001). Importantly, ∼80% of the patients experienced mild or even less aortic regurgitation as assessed by angiography after the procedure, without between-group differences. Postdilation and valve-in-valve rates were equivalent (24.7% vs 25%, p = 0.934 and 5.5% vs 3.4%, respectively, p = 0.217). No differences were revealed in the rates of death, cardiovascular death, and stroke or transient ischemic attack at 12-month follow-up. These results were sustained after propensity matching analysis. In conclusion, as long as a comprehensive procedural planning is performed, TAVI with CRS may be performed exclusively under angiographic guidance without the need for associated TEE.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2015.05.024DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
aortic valve
8
valve implantation
8
transesophageal echocardiography
8
outcomes tavi
8
underwent tavi
8
atee angio
8
patients included
8
tavi
5
angio
5

Similar Publications

Background: Current guidelines recommend transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis and porcelain aorta (PA). Neurological outcomes of patients with PA undergoing TAVI with modern valves require clarification as most trials examined balloon-expandable valves (BEV) and self-expandable valves in intermediate or high-risk patients, but not specifically in patients with PA. Our aim was to compare outcomes, including stroke and mortality, in well-matched patients with and without PA who received BEV during transfemoral TAVI procedures.

View Article and Find Full Text PDF

Unveiling the Fourth Dimension: Strain Analysis with Computed Tomography Scans in Transcatheter Aortic Valve Replacement Innovation.

Can J Cardiol

January 2025

Division of Cardiology, Department of Medicine, University of Toronto, Toronto, Canada; Division of Cardiology, Terrence Donnelly Heart Centre, St Michael's Hospital, 30 Bond Street, Toronto, Canada; Keenan Research Centre, Li Ka Shing Knowledge Institute, St Michael's Hospital, Toronto, Canada.

View Article and Find Full Text PDF

This study aims to evaluate the implementation of concomitant CAD assessment on pre-TAVI (transcatheter aortic valve implantation) planning CTA (CT angiography) aided by CT-FFR (CT-fractional flow reserve) [The CT2TAVI protocol] and investigates the incremental value of CT-FFR to coronary CT angiography (CCTA) alone in the evaluation of patients undergoing CT2TAVI. This is a prospective observational real-world cohort study at an academic health system on consecutive patients who underwent CTA for TAVI planning from 1/2021 to 6/2022. This represented a transition period in our health system, from not formally reporting CAD on pre-TAVI planning CTA (Group A) to routinely reporting CAD on pre-TAVI CTA (Group B; CT2TAVI protocol).

View Article and Find Full Text PDF

BACKGROUND Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure increasingly used to treat severe aortic stenosis, especially in elderly patients and those with significant comorbidities who are at high risk for surgical intervention. While TAVR is generally safe and effective, rare complications can occur, including cerebral air embolism, which can result in acute neurological deficits. This report presents the case of a 75-year-old man who developed a cerebral air embolism following TAVR.

View Article and Find Full Text PDF

Background: The optimal timing for percutaneous coronary intervention (PCI) in patients undergoing transcatheter aortic valve replacement (TAVR) is debatable.

Objectives: The aim of this study was to compare outcomes based on the timing of PCI in stable coronary artery disease patients undergoing TAVR.

Methods: Leveraging the STS/ACC TVT Registry and Medicare Linkage, we analyzed patients with stable coronary artery disease undergoing PCI and TAVR between 2015 and 2023 using the SAPIEN 3 balloon-expandable valve platform.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!