A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Ocular blood flow and carotid artery malfunction]. | LitMetric

Aim: to evaluate ocular hemodynamics and informativity of estimated individual normal range of intraocular pressure (IOP).

Materials And Methods: A total of 12 patients (22 eyes) with carotid artery malfunction were examined. Ocular blood flow (OBF) and IOP were measured with Ocular Blood Flow Analyzer. Actual OBF was then compared with what is considered normal for a given axial length (AL). Individual normal range of IOP was calculated according to an original formula (described in previous publications). Doppler imaging of ocular vessels enabled blood flow velocity measurement. Morphological parameters and functional status of the retina and optic nerve were judged on automated perimetry (Octopus 900) and optical coherence tomography (Cirrus HD-OCT) findings. Statistical analyses were performed using Statistica 10 software.

Results: Generally, OBF showed no correlation with the grade of carotid artery stenosis (p < 0.05), however, was significantly reduced as compared to its AL-dependent norm in patients with greater than 85% narrowing of the internal carotid artery, which can cause misestimating of their individual normal range of IOP. A negative relationship was established between the blood flow velocity in short posterior ciliary arteries and the grade of internal carotid artery stenosis (p < 0.005). Ocular blood flow deficit relative to the AL-dependent norm correlated with ophthalmic artery resistance index.

Conclusion: OBF-based estimation of individual normal range of IOP is inexpedient in patients with greater than 80% carotid artery stenosis due to its possible influence on ocular hemodynamics. In most cases of less than 80% carotid artery stenosis OBF is adequate or slightly reduced as compared to its AL-dependent norm and thus, has no significant impact on estimated individual normal range of IOP.

Download full-text PDF

Source
http://dx.doi.org/10.17116/oftalma2015131219-25DOI Listing

Publication Analysis

Top Keywords

carotid artery
28
blood flow
24
individual normal
20
normal range
20
range iop
16
artery stenosis
16
ocular blood
12
al-dependent norm
12
artery
8
ocular hemodynamics
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!