Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: To evaluate the diagnostic potential of Lugol's chromoendoscopy-guided confocal laser endomicroscopy (CLE) in detecting superficial esophageal squamous cell neoplasia (ESCN).
Methods: Between December 2008 and September 2010, a total of 52 patients were enrolled at the Chinese PLA General Hospital in Beijing, China. First, Lugol's chromoendoscopy-guided CLE was performed in these patients and the CLE in vivo histological diagnosis was recorded. Then, chromoendoscopy-guided biopsy was performed in the same patients by another endoscopist who was blinded to the CLE findings. Based on the biopsy and CLE diagnosis, en bloc endoscopic resection was performed. The CLE in vivo diagnosis and the histological diagnosis of biopsy of ESCN were compared, using a histological examination of the endoscopic resection specimens as the standard reference.
Results: A total of 152 chromoendoscopy-guided biopsies were obtained from 56 lesions. In the 56 lesions of 52 patients, a total of 679 CLE images were obtained vs 152 corresponding biopsies. The sensitivity, specificity, negative predictive value and positive predictive value of chromoendoscopy-guided CLE compared with biopsy were 95.7% vs 82% (P < 0.05), 90% vs 70% (P < 0.05), 81.8% vs 46.7% (P < 0.05), and 97.8% vs 92.7% (P > 0.05), respectively. There was a significant improvement in sensitivity, specificity, negative predictive value, and accuracy when comparing chromoendoscopy-guided CLE with biopsy.
Conclusion: Lugol's chromoendoscopy-guided CLE is a real-time, non-invasive endoscopic diagnostic technology; the accuracy of the detection of superficial ESCN is equivalent to or may be superior to biopsy histology.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462739 | PMC |
http://dx.doi.org/10.3748/wjg.v21.i22.6974 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!