Hyperglycemia, hypoglycemia, and glycemic variability have been associated with increased morbidity, mortality, length of stay, and cost in a variety of critical care and non-critical care patient populations in the hospital. The results from prospective randomized clinical trials designed to determine the risks and benefits of intensive insulin therapy and tight glycemic control have been confusing; and at times conflicting. The limitations of point-of-care blood glucose (BG) monitoring in the hospital highlight the great clinical need for an automated real-time continuous glucose monitoring system (CGMS) that can accurately measure the concentration of glucose every few minutes. Automation and standardization of the glucose measurement process have the potential to significantly improve BG control, clinical outcome, safety and cost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4525658PMC
http://dx.doi.org/10.1177/1932296815587938DOI Listing

Publication Analysis

Top Keywords

glucose monitoring
12
continuous glucose
8
hyperglycemia hypoglycemia
8
hypoglycemia glycemic
8
glycemic variability
8
glucose
5
vascular glucose
4
glucose sensor
4
sensor symposium
4
symposium continuous
4

Similar Publications

Flexible microcolumn array-based silk fibroin for sweat glucose monitoring.

Anal Chim Acta

May 2025

College of Textile Science and Engineering, Jiangnan University, 1800Lihu Road, Wuxi, 214122, China. Electronic address:

Flexible sweat sensors possess the special potential for continuous non-invasive monitoring of human blood glucose. We put forward a flexible microcolumn array sensor, which is designed for health monitoring by means of detecting glucose levels in sweat and capturing physiological signals related to human movement. With the combination of silk fibroin (SF), waterborne polyurethane (PU), and multi-walled carbon nanotubes (MWCNT), this microcolumn film electrode is able to effectively function as a strain sensor benefiting from the superior mechanical performance of PU.

View Article and Find Full Text PDF

Background: The imperative need for early cancer detection, which is crucial for improved survival rates in many severe cancers such as lung cancer, remains challenging due to the lack of reliable early-diagnosis technologies and robust biomarkers. To address this gap, innovative screening platforms are essential to unveil the chemical signatures of lung cancer and its treatments. It is established that the oxidative tumor environment induces alterations in host metabolic processes and influences endogenous volatile synthesis.

View Article and Find Full Text PDF

Background: The EMPA-REG OUTCOME trial confirmed empagliflozin reduced mortality and heart failure hospitalization risk. These findings raised the possibility that empagliflozin may modulate cardiac autonomic function in patients with type 2 diabetes (T2D).

Methods And Results: The EMPYREAN study was a prospective randomized open-label assessor-blinded multicenter investigation of patients with T2D without prior antidiabetic therapy with sodium-glucose cotransporter 2 or dipeptidyl peptidase 4 inhibitors.

View Article and Find Full Text PDF

We examined whether the glucose levels and awareness of individuals without diabetes changed after using a sensor-based intermittently scanned continuous glucose monitoring (isCGM) system in their daily lives. Japanese individuals without a diabetes diagnosis wore the isCGM system while maintaining a normal lifestyle during the baseline period. A certified diabetes educator coached them on how to improve their lifestyle based on information from sensor data, food journals, and body composition.

View Article and Find Full Text PDF

Context: In 2023, we employed Dexcom G6 for real-time continuous glucose monitoring (rt-CGM); it showed high usefulness but unsatisfactory accuracy in type 1 diabetes summer camp (camp) participants.

Objective: To assess the usefulness, recommendation and accuracy of a new rt-CGM system in camp, 2024.

Methods: Sensor glucose (SG) concentrations were measured by Dexcom G7 (G7) from 6 days prior to camp.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!