Experimental and theoretical proof is provided for the fact that a microfabricated packed bed column, which is uniformly filled with radially elongated pillars (REPs), can produce the same separation performance as nonpacked, open-tubular columns. These are generally recognized as the best possible chromatographic column format, offering the highest conceivable separation speed and efficiency. It is also demonstrated both experimentally and theoretically that, as long as pressure is not a limiting factor, the REP column format can even outperform the open-tubular column format, with significant gains in either speed or efficiency proportional to the tortuosity, τ, of the bed. Conducting chromatographic experiments on 4 cm long micromachined packed bed columns filled with radially elongated pillars, separation efficiencies corresponding to N = 160,000 theoretical plates (unretained analytes) and N = 70,000 theoretical plates were achieved, despite the relatively large interpillar distance (2.5 μm).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.5b01579 | DOI Listing |
Appl Microbiol Biotechnol
January 2025
Department of Chemistry, Biochemistry and Pharmaceutical Sciences, University of Bern, Freiestrasse 3, 3012, Bern, Switzerland.
A new strategy has been developed to successfully produce the active component danshensu ex vivo. For this purpose, phenylalanine dehydrogenase from Bacillus sphaericus was combined with the novel hydroxyphenylpyruvate reductase from Mentha x piperita, thereby providing an in situ cofactor regeneration throughout the conversion process. The purified enzymes were co-immobilized and subsequently employed in batch biotransformation, resulting in 60% conversion of 10 mM L-dopa within 24 h, with a catalytic amount of NAD as cofactor.
View Article and Find Full Text PDFNature
January 2025
Department of Chemical Engineering, University College London, London, UK.
Methane, the major component of natural and shale gas, is a significant carbon source for chemical synthesis. The direct partial oxidation of methane to liquid oxygenates under mild conditions is an attractive pathway, but the molecule's inertness makes it challenging to achieve simultaneously high conversion and high selectivity towards a single target product. This difficulty is amplified when aiming for more valuable products that require C-C coupling.
View Article and Find Full Text PDFACS Omega
January 2025
Department of Chemical Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia.
The discharge of chromium(VI) into the environment is becoming a significant global concern. Despite the existence of numerous techniques for chromium(VI) removal, substantial challenges persist in effectively mitigating this issue. Therefore, this study investigates the feasibility of using low-cost basalt rock as an adsorbent for chromium(VI) removal.
View Article and Find Full Text PDFChemSusChem
January 2025
CIC biomaGUNE, Heterogeneous Biocatalysis, Paseo Miramon 182, 20009, San Sebastian, SPAIN.
EEfficient methods for isolating N-glycans are essential to understanding the functions and characteristics of the entire N-glycome. Enzymatic release using PNGaseF is the most effective approach for releasing mammalian N-glycans for analytical purposes. However, the use of PNGaseF for preparative N-glycan isolation is precluded due to the enzyme's cost and limited stability.
View Article and Find Full Text PDFChemistry
January 2025
Université de Montréal, FRQNT Centre in Green Chemistry and Catalysis, Centre for Continuous Flow Synthesis, Department of Chemistry, 1375 av. Thérèse Lavoie-Roux, Montréal, QC, H2V 0B3, Canada.
The pentafluorosulfanyl (SF-) group has been the subject of a surge of interest in the past decade, but there is still little practicality associated with its synthesis and installation. Herein is reported the first continuous flow synthesis of pentafluorosulfanyl chloride (SFCl), the most common reagent for the synthesis of SF-substituted compounds. The synthesis is based on inexpensive and easy-to-handle reagents: sulfur powder (S), trichloroisocyanuric acid (TCCA) and potassium fluoride (KF).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!