This study presents a simple but sensitive HPLC chromatographic method with a stability-indicating assay for determination and physicochemical characterisation of L-carnosine, a promising senile cataract prophylactic agent. Chromatographic analysis was conducted using a reverse phase (RP)-HPLC system and an isocratic mobile phase of 98% v/v trifluoroacetic acid (0.1% v/v) and 2% v/v acetonitrile with detection at 220 nm. L-carnosine was subjected to stress conditions to force its degradation using chemical and thermal agents and was subsequently detected from its degradation products using ESI-MS. The lipophilicity of the drug and 1:1 drug to phospholipid complex (PC) mol/mol was determined by estimating the partition coefficient (P). Lipophilicity was greatly enhanced when L-carnosine was formulated as a phospholipid complex using the solvent evaporation method. L-carnosine-phospholipid complex could be a promising approach for effective delivery to the human lens as offers a potential novel treatment for senile cataract.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2015.05.025 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!