  • Study investigates cardiovascular effects of three intubation devices (MAC, UE, VS) on cardiac output and hemodynamics in normotensive and hypertensive patients.
  • Significant finding: intubation time was notably shorter in the UE group compared to MAC in both patient categories.
  • In hypertensive patients, MAC caused higher systolic and diastolic blood pressure immediately post-intubation compared to UE and VS, while other hemodynamic parameters showed no significant differences across devices.

Article Abstract

Tracheal intubation with Macintosh laryngoscope (MAC) might result in severe cardiovascular complications. The results of conducted studies investigating the effects of videolaryngoscopies on hemodynamic response of tracheal intubation are conflicting. We know little about the effects of videolaryngoscopies on cardiac output changes during tracheal intubation. We compared cardiac output (COP) and hemodynamic responses in normal blood pressure (n=60) and hypertensive patients (n=60) among 3 intubation devices: the MAC, the UE videolaryngoscopy ® (UE), and the UE video intubation stylet ® (VS). Cardiac index (CI), stroke volume index (SVI), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were recorded using LidcoRapid (V2)® preinduction, preintubation, and every minute for the first 5 min after intubation. We assessed oropharyngeal and laryngeal structures injury as well. Intubation time was significantly shorter than MAC groups (P<0.001) only in UE group of normotensive and hypertensive patients. In normotensive patients, there were no significant differences in any of COP variables or hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the MAC group were significantly higher (P<0.05 or <0.01) than the UE and VS groups at 1, 2 and 3 min after intubation, but there were no significant differences in CI, SVI and HR among the three devices. There was no significant difference in oropharyngeal and laryngeal structures injury among all groups. It was concluded that both the UE and VS attenuate only the hemodynamic response to intubation as compared with the MAC in hypertensive patients, but not in normotensive patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11596-015-1449-7DOI Listing

Publication Analysis

Top Keywords

cardiac output
12
tracheal intubation
12
blood pressure
12
hemodynamic responses
8
intubation
8
hypertensive patients
8
effects videolaryngoscopies
8
comparison cardiac
4
output hemodynamic
4
responses intubation
4

Similar Publications

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Circadian biology of cardiac aging.

J Mol Cell Cardiol

December 2024

Kinesiology & Health, University of Wyoming, Laramie, WY, USA; Zoology & Physiology, University of Wyoming, Laramie, WY, USA. Electronic address:

The age of the U.S. population is increasing alongside a growing burden of age-related cardiovascular disease.

View Article and Find Full Text PDF

Sheldon Magder's article on applying Arthur Guyton's principles to clinical fluid management provides valuable insights into optimizing hemodynamics in critically ill patients. While emphasizing the role of right atrial pressure (RAP) in assessing cardiac output, challenges arise due to RAP's variable accuracy and the oversimplification of cardiovascular dynamics. Integrating RAP with dynamic assessments and bedside ultrasound can enhance fluid management strategies.

View Article and Find Full Text PDF

Interscalene blocks, commonly used for shoulder surgery analgesia, often cause transient phrenic nerve palsy, leading to hemi-diaphragmatic paresis. This complication is particularly problematic in patients with pulmonary comorbidities and has been extensively investigated. However, its impact on patients with Fontan physiology remains less understood with limited representation in the literature.

View Article and Find Full Text PDF

Introduction: Elevated central aortic pressure, cardiac output and peripheral vascular resistance contribute to high morbidity in relation to end organ dysfunction in obstructive and non-obstructive coronary artery disease (NOCAD) cases despite revascularization. Bisoprolol preempts further progression of left ventricular dysfunction in such cases due to anti-ischemic and anti-hypertensive effects, further extending its evaluation in local Indian settings.

Methods: Post-hoc analyses of NOCAD patients with epicardial stenosis (N=378, 30 to 70% stenosis) from cross-sectional analyses conducted across eighty centers in India.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!