Purpose: The aim of this paper was to determine whether the change in the position of the patient's leg as well as the use of flexible reamers may help in obtaining a longer femoral tunnel with minimal risk of perforating the posterior cortex.
Methods: One hundred and twenty-five patients who had undergone anatomic ACL reconstruction between 2010 and 2013 were included in this prospective cohort study. The first group was composed of patients whose femoral tunnel had been drilled with rigid reamers, while the leg being operated on was positioned on an arthroscopic leg holder (82 patients). In the second group of patients, the femoral tunnel was also drilled with rigid reamers, but the leg was positioned on the table (25 patients), while the third group was composed of patients whose femoral tunnel was drilled with flexible reamers, and the leg was positioned on a leg holder (18 patients). The length of the femoral tunnel was measured intraoperationally, while the site of femoral insertion and the position of the tunnel were read from native radiographic images.
Results: When the femoral tunnel was drilled on the medial aspect of the lateral condyle, the centre of the tunnel was located at 31.4 % from the most proximal point of the femoral condyle and 34.7 % from the Blumensaat line. The length of the tunnel drilled with rigid reamers on the operating table (36.1 mm) was statistically significantly greater (p < 0.05) than the length of the tunnel drilled with the same reamers, but with the leg positioned on the leg holder (32.5 mm). The length of the tunnel drilled with flexible reamers with the leg positioned on the leg holder (42.5 mm) was highly statistically significantly greater than the length of the tunnel drilled with rigid reamers (p < 0.01), and it was statistically significantly greater than the length of the tunnel drilled with rigid reamers with the leg placed on the operating table (p < 0.05).
Conclusion: The drilling of the femoral tunnel during anatomic ACL reconstruction with the use of flexible reamers provides a longer femoral tunnel than when it is drilled with rigid reamers, without any danger of perforation of the posterior cortex.
Level Of Evidence: III.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00167-015-3670-0 | DOI Listing |
Unlabelled: The increased rate of anterior cruciate ligament (ACL) tears has led to a greater number of revisions. Revision surgery can be performed in one or two stages. Single-stage revision ACL reconstruction (ssRACLR) may be performed when prior tunnels can be re-used or bypassed whereas a two-stage procedure is indicated when bone grafting of dilated tunnels prior to revision is necessary.
View Article and Find Full Text PDFJ Clin Orthop Trauma
February 2025
Joints and Spine Clinic, Mahavir Nagar, Kandivali West, Mumbai, 400067, India.
Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Department of Orthopedic Surgery, Suez Canal University Hospital, Kilo 4.5 Ring Road, Ismailia, 41111, Egypt.
Introduction: As a result of increased incidence of anterior cruciate ligament (ACL) injury in young athletes, there is a rise in the indications surgical ACL reconstruction procedures. The value of anterolateral ligament (ALL) reconstruction emerges as a proposed solution to prevent graft failures and improve stability in this high demanding category of patients. The purpose of this study is to present our experience with a novel hamstring auto-grafting technique, the single antegrade sling graft (SASG), for combined reconstruction of both ACL and ALL using autologous gracilis (GR) and semitendinosus (ST) grafts utilizing a single femoral tunnel and double tibial tunnels.
View Article and Find Full Text PDFBackground And Aims: A catheter-related bloodstream infection (CRBSI) is a life-threatening complication of hemodialysis. It is responsible for significant morbidity and mortality and a costly long hospital stay. Despite its burden, little is known about the factors associated with it and the antibiogram of its responsible causative bacteria.
View Article and Find Full Text PDFAsia Pac J Sports Med Arthrosc Rehabil Technol
January 2025
Chinese University of Hong Kong, Hong Kong SAR, China.
This technical note explores the novel use of an imageless robotic surgical system for simultaneous unicompartmental knee arthroplasty (UKA) and anterior cruciate ligament reconstruction (ACLR). Knee osteoarthritis (OA) and anterior cruciate ligament (ACL) insufficiency are common conditions that traditionally require separate management. The integration of robotic assistance offers enhanced precision in surgical procedures, addressing both medial compartment OA and ACL insufficiency in a single operation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!