A PAT-based qualification of pharmaceutical excipients produced by batch or continuous processing.

J Pharm Biomed Anal

Quality Operations, Laboratory for Liquid Products, Merck Serono, Frankfurter Str. 250, 64293 Darmstadt, Germany. Electronic address:

Published: October 2015

AI Article Synopsis

Article Abstract

Pharmaceutical excipients have an influence on the main requirements for medicinal products (viz., quality, safety and efficacy) but also on their manufacturability. During product lifecycle it may become necessary to introduce minor changes (e.g., to continuously improve it) or major changes in the validated process (e.g., moving it to a new production site, replacing process version or even disruptively changing processing type). Those changes can influence the critical to quality attributes of the product. Therefore, it is important to enhance process understanding to avoid the risk of any significant quality changes. Process analytical technology can support better decision making and risk-management as required in quality by design - viz., by many pharmaceutical regulatory authorities. This study compares the quality of the pharmaceutical excipient sodium carbonate (anhydrous) produced either in a batch or a continuous process. For continuous processing two different production lines were available that differed on the dryer and crystallizer types used. Therefore their influence on critical to quality attributes of sodium carbonate was investigated for each of the three processing alternatives. The overall goal was to identify which of the continuous processes ensures a similar product quality to batch processing. Namely, changes on chemical and physical attributes of the product were investigated with Raman spectroscopy, laser diffraction and X-ray powder diffraction. Principal component analysis, a very common multivariate analysis technique, was applied to extract relevant information from small differences at multiple spectral regions from samples from each process type and from each analytical technique used. Changing processing from batch to continuous improved consistency of certain attributes (e.g., particle size distribution) but affected others. However, the increased process/product knowledge gained can lead to an enhanced control strategy and ensure a similar product quality is obtained from distinct process versions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2015.05.012DOI Listing

Publication Analysis

Top Keywords

batch continuous
12
pharmaceutical excipients
8
produced batch
8
continuous processing
8
quality
8
changing processing
8
influence critical
8
critical quality
8
quality attributes
8
attributes product
8

Similar Publications

Metal nanoparticles are established tools for biomedical applications due to their unique optical properties, primarily attributed to localized surface plasmon resonances. They show distinct optical characteristics, such as high extinction cross-sections and resonances at specific wavelengths, which are tunable across the wavelength spectrum by modifying the nanoparticle geometry. These attributes make metal nanoparticles highly valuable for sensing and imaging in biology and medicine.

View Article and Find Full Text PDF

Continuous-flow phosphate removal using Cry-Ca-COS Monolith: Insights from dynamic adsorption modeling.

Water Res X

May 2025

Integrated Science and Technology Research Center, Faculty of Technology and Environment, Prince of Songkla University, Phuket Campus, Kathu, Phuket 83120 Thailand.

This study rigorously evaluates the adsorption performance of the Cry-Ca-COS monolith for phosphate removal in a column operation mode. Characterization of the material both before and after exhaustion in a continuous flow system (column form) showed no difference compared to results from a batch system (tablet form). The XPS results indicated that the adsorption mechanism of phosphate on the Cry-Ca-COS column involved surface microprecipitation and ligand exchange (inner-sphere complexation).

View Article and Find Full Text PDF

Continuous flow solvent-free and catalyst-free mechanochemical production of rhodamine B dyes and their derivatives.

Chem Commun (Camb)

January 2025

Chemical Engineering & Process Development, CSIR-National Chemical Laboratory Pune, 411008, India.

In this communication, we have described a simple and efficient, catalyst free and solvent-free protocol for the continuous flow synthesis of rhodamine B dyes developed from 3-diethyl amino phenol and phthalic anhydride. Nearly 95% conversion was achieved within 12 min using a jacketed single screw reactor. This method is further used for the synthesis of six derivatives with 70-84% yield, which can be compared to 85% yield from a 1-hour long batch synthesis involving a catalyst.

View Article and Find Full Text PDF

Tablet diversion strategy based on in-line NIR tablet press feed frame measurements.

Int J Pharm

January 2025

Pharmaceutical Engineering Research Group (PharmaEng), Department of Pharmaceutical Analysis, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium. Electronic address:

The tablet diversion strategy, based on in-line near-infrared (NIR) tablet press feed frame measurements, can be a key component of both batch and continuous oral solid dose manufacturing processes. It enables real-time, high-frequency monitoring and control, enhancing process understanding and compliance compared to conventional interval-based sampling methods. Central to this strategy are NIR spectrometers, which serve as PAT systems for in-line blend uniformity monitoring in the feed of the tablet press.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!