Purpose: The present study was conducted to determine corneal topographic characteristics of children with vernal keratoconjunctivitis (VKC) and compare the corneal topographic indices in VKC subjects with normal subjects
Material And Method: In the hospital based comparative study, 115 consecutive subjects with VKC and 102 age and sex matched normal subjects were selected for the videokeratography with NIDEK ophthalmic operating system. Keratoconus-like topography was determined based on the expert classifier system. Other assessments included visual acuity testing with LogMAR chart, slit lamp biomicroscopy, dilated fundus examination, measurement of central corneal thickness and intraocular pressure. Topographic indices were analyzed and compared using unpaired t-test among different groups. Sensitivity and specificity was estimated by the ROC curve.
Result: Among 115 subjects with VKC, males comprised of 86 subjects (66.1%) and mean age of presentation was 10.9 (SD 4.9) years with mixed VKC in 56.5%. Keratoconus-like topography was present in 13 subjects (11.3%). The keratoconus predictiv index (sensitivity 92.3%, specificity 98.5%), the opposite sectoral index (sensitivity 84.6%; specificity 93.2%), the differential sectoral index (sensitivity 92.3%; specificity 90.8%) were found to be signficantly associated with VKC subjects having keratoconus-like topography.
Conclusion: A high prevalence of keratoconus-like topography was observed in patients with VKC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2015.05.013 | DOI Listing |
Cochrane Database Syst Rev
November 2023
University Eye Clinic Maastricht, Maastricht University Medical Center (MUMC+), Maastricht, Netherlands.
Background: Keratoconus remains difficult to diagnose, especially in the early stages. It is a progressive disorder of the cornea that starts at a young age. Diagnosis is based on clinical examination and corneal imaging; though in the early stages, when there are no clinical signs, diagnosis depends on the interpretation of corneal imaging (e.
View Article and Find Full Text PDFCont Lens Anterior Eye
August 2023
Department of Ophthalmology, Tri-Service General Hospital and School of Medicine, National Defense Medical Center, Taipei, Taiwan, Republic of China. Electronic address:
Purpose: This study aimed to evaluate corneal topographic findings in patients with thyroid eye disease (TED) using a Galilei camera and compare their corneal topographic parameters with those of control patients.
Methods: This retrospective cross-sectional study included 52 eyes of 26 patients with TED (study group) and 40 eyes of 20 controls treated at a tertiary medical center in Taiwan between January and December 2021. All participants underwent basic ophthalmological examinations, corneal topography examination using a Galilei dual Scheimpflug camera, thyroid function examination, and orbital computed tomography.
BMJ Case Rep
July 2022
Refractive Surgery, Narayana Nethralaya, Bangalore, Karnataka, India.
A woman in her late twenties presented with blurring of vision in the right eye for 6 years. Retinoscopy showed a scissoring reflex in the right eye with best spectacle-corrected visual acuity of 20/40 in the right eye and 20/20 in the left eye. Slit-lamp examination of the right eye showed superior crescentic thinning with conjunctivalisation and lipid deposition while the left eye was normal.
View Article and Find Full Text PDFClin Ophthalmol
October 2019
Department of Ophthalmology, University of Lausanne, Jules-Gonin Eye Hospital, Foundation Asile des Aveugles, Lausanne, Switzerland.
Purpose: To present six patients with keratoconus-like topographic changes due to inferior inhomogenous epithelial thickening, demonstrated by AS-OCT epithelium map.
Patients And Methods: We present twelve eyes of six patients evaluated in the refractive surgery consultation with Pentacam HR Scheimpflug rotating camera system, presenting topographical irregularities suggestive of keratoconus. Slit-lamp examination, best-corrected visual acuity, Scheimpflug tomography and anterior segment optical coherence tomography epithelium map (Optovue ) were conducted and analyzed.
Optom Vis Sci
September 2019
College of Optometry, University of Houston, Houston, Texas.
Significance: The challenges associated with clinical assessment of individuals with Down syndrome contribute to a wide range of estimates on the prevalence of keratoconus in the Down syndrome population. This work focuses on two topographical indices previously identified with keratoconus detection, applying them to a topographical data set meeting strict sampling criteria.
Purpose: The purpose of this study was to quantify the level of keratoconus-like topographical morphology in a large sample of eyes from individuals with Down syndrome, as identified by two keratoconus detection metrics: inferior-superior dioptric asymmetry (I-S) and KISA%.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!