A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

One-Year Clinical and Radiological Results of a Prospective, Investigator-Initiated Trial Examining a Novel, Purely Autologous 3-Dimensional Autologous Chondrocyte Transplantation Product in the Knee. | LitMetric

Background: The 3-dimensional autologous chondrocyte transplantation (ACT3D) comprises isolation of chondrocytes from cartilage biopsies, cultivation to spheroids, and transplantation into the cartilage defect.

Objectives: To evaluate the patients' general health and functionality and to assess the defect repair after ACT3D with spheroids by MRI and MOCART scoring.

Methods: Thirty-seven patients with isolated chondral lesions of the knee underwent ACT3D with spheroids through medial arthrotomy. Patient-administered scores were assessed at baseline (day before transplantation), at 6 weeks, and at 3, 6, and 12 months. MRI and MOCART scoring were performed at 3 and 12 months after ACT3D.

Results: Patients were diagnosed with full-thickness patellofemoral (n = 16), femoral condylar (n = 18), or both defect types (n = 3), International Cartilage Repair Society (ICRS) grade 3 or 4, with defect sizes between 1.0 and 12.0 cm(2). On average, 59.5 spheroids/cm(2) in defect size were transplanted. An overall statistically significant improvement from baseline to 12 months was observed for all assessment scores (Lysholm, International Knee Documentation Committee [IKDC], SF-36, Tegner) combined with a significant reduction in the visual analog scale (VAS) for pain and an advanced defect filling. Subgroup analyses revealed a positive clinical outcome independent on defect size, defect locations, spheroid dosage, age, duration of symptoms, and severity of complaints at baseline. Seven patients experienced in total 8 adverse events, of which knee joint effusion and blocking were assessed as possibly or probably related to ACT3D.

Conclusions: The patient-administered assessment scores along with the fast defect filling with ACT3D using spheroids demonstrated an increase in activity level and quality of life after a 1-year follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4297188PMC
http://dx.doi.org/10.1177/1947603511417616DOI Listing

Publication Analysis

Top Keywords

act3d spheroids
12
3-dimensional autologous
8
autologous chondrocyte
8
chondrocyte transplantation
8
defect
8
mri mocart
8
defect size
8
assessment scores
8
defect filling
8
one-year clinical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!