The role of femoral offset and abductor lever arm in total hip arthroplasty.

J Orthop Traumatol

Østfold Hospital Trust, Aleris Health Oslo, Chr. Svendsens gate 6, 1771, Halden, Norway.

Published: December 2015

Background: In order to create a well-functioning total hip arthroplasty (THA), it is important to restore femoral off-set and thus the abductor lever arm. The aim of this study was to investigate the clinical effect of increasing the abductor lever arm to and beyond the anatomical native lever arm in minimally invasive total hip arthroplasty performed through a direct anterior approach.

Materials And Methods: We compared the lever arm of the operated hip to the lever arm of the contralateral native hip on radiographs in 148 patients following THA. The patients were divided in two groups based on whether they kept their anatomical lever arm or had an increased lever arm. The clinical outcome was assessed using hip osteoarthritis outcome score (HOOS), Harris hip score and UCLA activity score.

Results: Patients who kept their anatomical lever arm did not experience a significantly better clinical outcome than the patients with an increased abductor lever arm. We found no significant difference in clinical scores at any of the follow-ups during the first year after THA.

Conclusion: The results of this study suggest that an increase in the abductor lever arm does not have major effects on the clinical outcome after THA. To avoid the potential negative effects of decreasing the lever arm, the surgeon should aim for an equal or slightly increased lever arm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4633429PMC
http://dx.doi.org/10.1007/s10195-015-0358-7DOI Listing

Publication Analysis

Top Keywords

lever arm
52
abductor lever
20
lever
13
arm
13
total hip
12
hip arthroplasty
12
clinical outcome
12
anatomical lever
8
increased lever
8
hip
7

Similar Publications

Background: Operative management of chronic Achilles tendinopathy with large defects can be surgically challenging. Concerns exist regarding transosseous transfer of the flexor hallucis longus (FHL) tendon because of the shortened lever arm of flexion and weakening of the big toe. The aim of this study was to demonstrate the 2-year outcome of transosseous FHL transfer for the treatment of large Achilles tendon defects.

View Article and Find Full Text PDF

Understanding structure-mechanical activity relationships (SMARs) in polymer mechanochemistry is essential for the rational design of mechanophores with desired properties, yet SMARs in noncovalent mechanical transformations remain relatively underexplored. In this study, we designed a subset of diarylethene mechanophores based on a lever-arm hypothesis and systematically investigated their mechanical activity toward a noncovalent-yet-chemical conversion of atropisomer stereochemistry. Results from Density functional theory (DFT) calculations, single-molecule force spectroscopy (SMFS) measurements, and ultrasonication experiments collectively support the lever-arm hypothesis and confirm the exceptional sensitivity of chemo-mechanical coupling in these atropisomers.

View Article and Find Full Text PDF

Patients with knee osteoarthritis (KOA) often have impaired muscle function of the weight-bearing muscles, particularly in the knee and hip joints. This can lead to a significant loss of strength and power and may play a role in the perceived instability of the knee joint. The purpose of this study was to compare the maximum isometric strength of the hip abductor and knee extensor muscles between patients with KOA with and without perceived instability.

View Article and Find Full Text PDF

Effect of archwire size and lever arm length on anterior and posterior teeth movement during en-masse retraction in personalized lingual orthodontics: A 3-dimensional finite element study.

Int Orthod

December 2024

Department of Orthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China. Electronic address:

Article Synopsis
  • The study aimed to analyze how different archwire sizes and lever arm lengths affect tooth movement during en-masse retraction in lingual orthodontics.
  • Different archwires with specific dimensions and extra torques were tested, and various lever arm lengths were used to exert a consistent force of 1.5N.
  • Results showed that thicker archwires and longer lever arms improved the control and effectiveness of moving anterior teeth while also influencing the positioning of posterior teeth.
View Article and Find Full Text PDF

: The management of residual elbow instability is a challenging and compelling issue for treating physicians. To overcome inherent drawbacks of dynamic external fixators, the internal joint stabilizer (IJS) has been developed, achieving successful results, but it can sometimes cause local tenderness or anesthetic concerns in the subcutaneous layer. In addition, a bulky anconeus can pull the hardware away from the axis of rotation with an increase in the lever arm and potential issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!