Assessment of volatile organic compound and hazardous air pollutant emissions from oil and natural gas well pads using mobile remote and on-site direct measurements.

J Air Waste Manag Assoc

a Oak Ridge Institute of Science and Education Fellowship, U.S. Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Research Triangle Park , NC , USA.

Published: September 2015

Unlabelled: Emissions of volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) from oil and natural gas production were investigated using direct measurements of component-level emissions on pads in the Denver-Julesburg (DJ) Basin and remote measurements of production pad-level emissions in the Barnett, DJ, and Pinedale basins. Results from the 2011 DJ on-site study indicate that emissions from condensate storage tanks are highly variable and can be an important source of VOCs and HAPs, even when control measures are present. Comparison of the measured condensate tank emissions with potentially emitted concentrations modeled using E&P TANKS (American Petroleum Institute [API] Publication 4697) suggested that some of the tanks were likely effectively controlled (emissions less than 95% of potential), whereas others were not. Results also indicate that the use of a commercial high-volume sampler (HVS) without corresponding canister measurements may result in severe underestimates of emissions from condensate tanks. Instantaneous VOC and HAP emissions measured on-site on controlled systems in the DJ Basin were significantly higher than VOC and HAP emission results from the study conducted by Eastern Research Group (ERG) for the City of Fort Worth (2011) using the same method in the Barnett on pads with low or no condensate production. The measured VOC emissions were either lower or not significantly different from the results of studies of uncontrolled emissions from condensate tanks measured by routing all emissions through a single port monitored by a flow measurement device for 24 hr. VOC and HAP concentrations measured remotely using the U.S. Environmental Protection Agency (EPA) Other Test Method (OTM) 33A in the DJ Basin were not significantly different from the on-site measurements, although significant differences between basins were observed.

Implications: VOC and HAP emissions from upstream production operations are important due to their potential impact on regional ozone levels and proximate populations. This study provides information on the sources and variability of VOC and HAP emissions from production pads as well as a comparison between different measurement techniques and laboratory analysis protocols. On-site and remote measurements of VOC and HAP emissions from oil and gas production pads indicate that measurable emissions can occur despite the presence of control measures, often as a result of leaking thief hatch seals on condensate tanks. Furthermore, results from the remote measurement method OTM 33A indicate that it can be used effectively as an inspection technique for identifying oil and gas well pads with large fugitive emissions.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10962247.2015.1056888DOI Listing

Publication Analysis

Top Keywords

voc hap
24
emissions
17
hap emissions
16
emissions condensate
12
condensate tanks
12
volatile organic
8
hazardous air
8
emissions oil
8
oil natural
8
natural gas
8

Similar Publications

NiN-Passivated NiO Hole-Transport Layer Improves Halide Perovskite-Based Solar Cell.

ACS Appl Mater Interfaces

October 2022

Department of Chemistry and Bar-Ilan Institute for Nanotechnology & Advanced Materials, Bar-Ilan University, Ramat Gan5290002, Israel.

The interfaces between inorganic selective contacts and halide perovskites (HaPs) are possibly the greatest challenge for making stable and reproducible solar cells with these materials. NiO, an attractive hole-transport layer as it fits the electronic structure of HaPs, is highly stable and can be produced at a low cost. Furthermore, NiO can be fabricated via scalable and controlled physical deposition methods such as RF sputtering to facilitate the quest for scalable, solvent-free, vacuum-deposited HaP-based solar cells (PSCs).

View Article and Find Full Text PDF

Controlling of volatile organic compound (VOC) emitted from industrial processes as most abundant and harmful air pollutant, has become one of the most important global environmental issues due to the rapid urbanization and industrialization. As an alternative and new type catalyst instead of conventional noble-metal nanoparticles widely utilized in oxidative decomposition of VOC, here we report the superior catalytic performance with 100% CO/CO conversion on hydroxyapatite (HAp, Ca(PO)(OH)) with structurally well-controlled active surface tailored via facile one-step mechanochemical treatment in ambient air. With detailed characterizations of particle morphology, crystallinity and chemical structure with respects to surface defect/oxygen vacancy formation, acidity/basicity and VOC affinity on HAps activated through different mechanical stresses when altered ball size is utilized in planetary ball-milling assisted mechanochemical process, it was found that the predominant defect/oxygen vacancy generation in PO site and enhanced basic site population established by selective mechanochemical activation of c-plane, facilitates the favorable catalytic oxidation route towards highly-efficient CO/CO conversion of VOC.

View Article and Find Full Text PDF

Background: Hospital-acquired pneumonia (HAP) is a common problem in intensive care medicine and the patient outcome depends on the fast beginning of adequate antibiotic therapy. Until today pathogen identification is performed using conventional microbiological methods with turnaround times of at least 24 h for the first results. It was the aim of this study to investigate the potential of headspace analyses detecting bacterial species-specific patterns of volatile organic compounds (VOCs) for the rapid differentiation of HAP-relevant bacteria.

View Article and Find Full Text PDF

Unlabelled: Present study reports the characterization results of settled dust particles in different indoor micro-environments of an academic institution in India. Field emission scanning electron microscope analysis of indoor dust revealed the presence of mineral particles, fly ash, and soot particles of different morphologies. Energy-dispersive X-ray spectroscopy analysis of indoor dust indicated that crystal particles are comprised of elements such as C, O, Na, Mg, Al, Si, S, Cl, K, Ca, Fe, and Ti.

View Article and Find Full Text PDF

Pulmonary infections in critical/intensive care - rapid diagnosis and optimizing antimicrobial usage.

Curr Opin Pulm Med

May 2017

Division of Pulmonary Sciences and Critical Care Medicine, Department of Medicine, Denver Health Medical Center, School of Medicine, University of Colorado, Denver, Colorado, USA.

Purpose Of Review: Diagnosis of pulmonary infection, including hospital-acquired pneumonia (HAP) and ventilator-associated pneumonia (VAP) in the critically ill patient remains a common and therapeutically challenging diagnosis with significant attributable morbidity, mortality, and cost. Current clinical approaches to surveillance, early detection and, conventional culture-based microbiology are inadequate for optimal targeted antibiotic treatment and stewardship. Efforts to enhance diagnosis of HAP and VAP and the impact of these novel approaches on rational antimicrobial selection and stewardship are the focus of recent studies reviewed here.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!