Background: Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety and efficacy of these devices are unknown. Many recent studies have now reported extended follow-up data.

Objectives: This study sought to investigate the long-term safety and efficacy of durable polymer-based DES, bioabsorbable polymer-based biolimus-eluting stents (BES), and BMS by means of network meta-analysis.

Methods: Randomized controlled trials comparing DES to each other or to BMS were searched through MEDLINE, EMBASE, and Cochrane databases and proceedings of international meetings. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted.

Results: Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target-vessel revascularization were reduced with all DES compared with BMS, with cobalt-chromium EES, platinum chromium-EES, SES, and BES also having lower target-vessel revascularization rates than PES.

Conclusions: After a median follow-up of 3.8 years, all DES demonstrated superior efficacy compared with BMS. Among DES, second-generation devices have substantially improved long-term safety and efficacy outcomes compared with first-generation devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2015.04.017DOI Listing

Publication Analysis

Top Keywords

long-term safety
16
safety efficacy
16
lower rates
12
stents
8
median follow-up
8
follow-up years
8
myocardial infarction
8
infarction bms
8
ses bes
8
target-vessel revascularization
8

Similar Publications

Comparative analysis of efficacy and quality of life between totally extraperitoneal sublay and intraperitoneal onlay mesh repair for ventral hernia.

Sci Rep

January 2025

Department of General Surgery, Shaoxing Central Hospital (The Central Affiliated Hospital, Shaoxing University), Shaoxing, 312030, Zhejiang Province, China.

Ventral hernias pose a prevalent challenge in abdominal wall surgery, with ongoing advancements in repair techniques designed to enhance patient outcomes. This study evaluates the efficacy, safety, and socio-economic impact of Totally Extraperitoneal Sublay Repair (TES) versus Laparoscopic Intraperitoneal Onlay Mesh Repair (IPOM) for small to medium-sized ventral hernias, with a particular focus on postoperative quality of life and patient satisfaction. A retrospective cohort study was conducted, encompassing 125 patients who underwent ventral hernia repair between May 2018 and November 2023.

View Article and Find Full Text PDF

Background: Chronic myeloid leukemia (CML) treatment has significantly evolved with the introduction of tyrosine kinase inhibitors. However, access to these treatments and outcomes vary globally. This study examines 2 decades of CML management in Colombia using the RENEHOC registry, focusing on TKI efficacy, safety, and healthcare system challenges.

View Article and Find Full Text PDF

Background: Drug-coated balloons (DCB) can decrease the incidence of restenosis in the treatment of intracranial atherosclerotic stenosis (ICAS). This study aimed to assess the safety and efficacy of submaximal angioplasty with DCB dilation compared with aggressive angioplasty in patients with symptomatic ICAS.

Methods: This study prospectively and consecutively enrolled patients with symptomatic ICAS who underwent DCB angioplasty between January 2021 and December 2023.

View Article and Find Full Text PDF

Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.

View Article and Find Full Text PDF

Background: Given burdensome side-effects and long latency for efficacy with conventional agents, there is a continued need for generalised myasthenia gravis treatments that are safe and provide consistently sustained, long-term disease control. Nipocalimab, a neonatal Fc receptor blocker, was associated with dose-dependent reductions in total IgG and anti-acetylcholine receptor (AChR) antibodies and clinically meaningful improvements in the Myasthenia Gravis Activities of Daily Living (MG-ADL) scale in patients with generalised myasthenia gravis in a phase 2 study. We aimed to assess the safety and efficacy of nipocalimab in a phase 3 study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!