Objectives: To evaluate the differences in prognostic values of static and dynamic PET-CT in nasopharyngeal carcinoma (NPC).

Material And Methods: Forty-five patients who had static scan were recruited. Sixteen had dynamic scan. The primary lesions were delineated from standardized uptake value (SUV) maps from static scan and K i maps from dynamic scan. The average follow-up lasted for 34 months. The patients who died or those with recurrence/residual disease were considered "poor outcome"; otherwise they were considered "good outcome." Fisher's exact test and ROC analysis were used to evaluate the prognostic value of various factors.

Results: Tumor volume thresholded by 40% of maximal SUV (VOLSUV40) significantly predicted treatment outcome (p = 0.024) in the whole cohort. In 16 patients with dynamic scan, all parameters by dynamic scan were insignificant in predicting the outcome. The combination of maximal SUV, maximal K i , VOLSUV40, and VOL K i 37 (the tumor volume thresholded by 37% maximal K i ) achieved the highest predicting accuracy for treatment outcome with sensitivity, specificity, and accuracy of 100% in these 16 patients; however this improvement compared to VOLSUV40 was insignificant.

Conclusion: Tumor volume from static scan is useful in NPC prognosis. However, the role of dynamic scanning was not justified in this small cohort.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431179PMC
http://dx.doi.org/10.1155/2015/582614DOI Listing

Publication Analysis

Top Keywords

dynamic scan
16
static scan
12
tumor volume
12
pet-ct nasopharyngeal
8
nasopharyngeal carcinoma
8
dynamic scanning
8
volume thresholded
8
maximal suv
8
treatment outcome
8
dynamic
7

Similar Publications

Computational exploration of injection strategies for improving medicine distribution in the liver.

Comput Biol Med

December 2024

Faculty of Chemical & Petroleum Engineering, University of Tabriz, Tabriz, Iran. Electronic address:

Background And Objectives: The liver, a vital metabolic organ, is always susceptible to various diseases that ultimately lead to fibrosis, cirrhosis, acute liver failure, chronic liver failure, and even cancer. Optimal and specific medicine delivery in various diseases, hepatectomy, shunt placement, and other surgical interventions to reduce liver damage, transplantation, optimal preservation, and revival of the donated organ all rely on a complete understanding of perfusion and mass transfer in the liver. This study aims to simulate the computational fluid dynamics of perfusion and the temporal-spatial distribution of a medicine in a healthy liver to evaluate the hemodynamic characteristics of flow and medicine transport with the purpose of more effective liver treatment.

View Article and Find Full Text PDF

A digital workflow for integrating diagnostic dentures into dynamic navigation-guided implant surgery.

J Prosthet Dent

December 2024

Professor, Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, PR China. Electronic address:

Article Synopsis
  • The dual cone beam computed tomography (CBCT) method is the standard approach for planning implant treatments in patients without teeth, but it is complicated and slow for real-time surgery.
  • A new technique introduced in the article simplifies this process by using a single CBCT scan registration method.
  • This new method incorporates information from diagnostic dentures into real-time navigation, making the implant planning more efficient.
View Article and Find Full Text PDF

Statement Of Problem: The accuracy of the interproximal and occlusal contacts of single posterior implant-supported restorations designed using computer-aided design (CAD) software programs remains uncertain.

Purpose: The aim of this clinical study was to assess the interproximal and occlusal contacts of single posterior implant-supported restorations designed with 2 distinct dental CAD software programs.

Material And Methods: Forty single posterior implant-supported restorations were evaluated for interproximal and occlusal contacts.

View Article and Find Full Text PDF

Background: Cerebrospinal fluid (CSF) motion and pulsatility has been proposed to play a crucial role in clearing brain waste. Although its driving forces remain debated, increasing evidence suggests that large amplitude vasomotion drives such CSF fluctuations. Recently, a fast blood-oxygen-level-dependent (BOLD) fMRI sequence was used to measure the coupling between CSF fluctuations and low-frequency hemodynamic oscillations in the human cortex.

View Article and Find Full Text PDF

Atraumatic bilateral femoral neck fractures are rare, especially in younger patients and those without significant comorbidities. However, pregnant individuals appear to be at increased risk due to normal physiological changes in calcium balance, leading to transient osteoporosis of the hip. In these individuals, calcium and bone mineral density are generally decreased, reflecting the calcium demands of the developing fetus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!