The effect of patent foramen ovale closure in patients with platypnea-orthodeoxia syndrome.

Catheter Cardiovasc Interv

Program in Interventional Cardiology, Division of Cardiology, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California.

Published: October 2015

Background: Platypnea-orthodeoxia syndrome is a rare condition characterized by hypoxemia in the upright position that is improved in the supine position. Although several etiologies of platypnea-orthodeoxia exist, it is frequently associated with right-to-left shunting of blood at the cardiac or pulmonary level, usually via a patent foramen ovale (PFO). The aim of this study was to evaluate the incidence of platypnea-orthodeoxia syndrome in a select patient population with right-to-left shunting and to describe the outcomes after PFO closure.

Methods: Patients with platypnea-orthodeoxia were prospectively identified from a population of patients who had a PFO and were referred to UCLA from 2001 to 2012. Those patients who elected to have their PFO closed were assessed for the severity of their symptoms and interval SaO2 changes. The changes in SaO2 before and after closure were compared in the supine and upright position. Patients were classified depending on the result of PFO closure as having "improved SaO2 " or "no change."

Results: Of 683 patients with PFO-associated conditions, 17 (2.5%) had platypnea-orthodeoxia and elected to close their PFO. The results in 11 of 17 patients (64.8%) were classified as having "improved SaO2 "; they experienced improvement or complete resolution of their dyspnea and hypoxemia (improved SaO2 from baseline 5.2 ± 4.7% when recumbent and 15.6 ± 3.0% when upright, P = 0.03 and P < 0.0001, respectively). Patients with no change after PFO closure predominantly had a pulmonary etiology for their hypoxia, with elevated mean pulmonary pressures measured before closure (51.4 ±16.8 mmHg, P = 0.06).

Conclusion: PFO closure may resolve symptomatic postural dyspnea and hypoxemia and is an effective method for treating platypnea-orthodeoxia, but is not effective when the primary etiology of the hypoxemia is due to a pulmonary cause.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.25953DOI Listing

Publication Analysis

Top Keywords

platypnea-orthodeoxia syndrome
12
pfo closure
12
patent foramen
8
foramen ovale
8
patients
8
patients platypnea-orthodeoxia
8
upright position
8
right-to-left shunting
8
pfo
8
"improved sao2
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!