Comparison between EGSnrc, Geant4, MCNP5 and Penelope for mono-energetic electron beams.

Phys Med Biol

Measurement Science and Standards, National Research Council of Canada, Ottawa K1A 0R6, Canada.

Published: July 2015

A simple geometry is chosen to highlight similarities and differences of current electron transport algorithms implemented in four Monte Carlo codes commonly used in radiation physics. Energy deposited in a water-filled sphere by mono-energetic electron beams was calculated using EGSnrc, Geant4, MCNP5 and Penelope as the radius of the sphere varied from 0.25 cm to 4.5 cm for beam energies of 0.5 MeV, 1.0 MeV and 5.0 MeV. The calculations were performed in single-scattering mode (where applicable) and in condensed history mode. A good agreement is found for the single-scattering calculations except for the in-air case at 0.5 MeV where differences increase with decreasing radius up to 5% between EGSnrc and Penelope. Differences between results calculated with the default user settings when compared to their own single-scattering modes are under 5% for all codes when the sphere is surrounded by vacuum, however, large differences occur for Geant4, MCNP5 and Penelope when air is introduced around the sphere. Finally, the parameters associated with the multiple scattering algorithms were tuned reducing these differences below 10% for these codes at the expense of increased computation time.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/60/13/4951DOI Listing

Publication Analysis

Top Keywords

geant4 mcnp5
12
mcnp5 penelope
12
egsnrc geant4
8
mono-energetic electron
8
electron beams
8
differences
5
comparison egsnrc
4
penelope
4
penelope mono-energetic
4
beams simple
4

Similar Publications

In this paper, the investigation of the Electron-Photon Interaction Cross Sections 2017 (EPICS2017) library on the shielding characteristics of several glasses under various chemical systems is presented. The EPICS2017 library of ENDF/B-VIII was interpolated to calculate the mass attenuation coefficients (MACs) of selected glass systems. Results from EPICS2017 have been compared with values from experimental and theoretical methods used to evaluate the photon shielding properties.

View Article and Find Full Text PDF

Monte Carlo simulations, MCNP5 and Geant4 codes were developed to investigate radiation shielding properties of xPbO-(50-x) BaO-50B2O3 (where 5 ≤ x ≤ 45 mol%) consider to be glass systems. The mass attenuation coefficients were evaluated for different PbO concentration in the glass samples for varies photon energies of 0.356, 0.

View Article and Find Full Text PDF

Monte Carlo calculations of electrons impinging on a copper target: A comparison of EGSnrc, Geant4 and MCNP5.

Appl Radiat Isot

February 2018

National Research Council Canada, 1200 Montreal Road, Ottawa ON, Canada K1A 0R6. Electronic address:

A simple geometry is used to compare several of the available Monte Carlo software codes for radiation transport. EGSnrc, Geant4 and MCNP5 are all used to calculate the photon fluence produced from electrons incident on a copper target. Four energies for the isotropic point source are chosen to simulate the average and maximum emission energies of P and Y: (0.

View Article and Find Full Text PDF

Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross-sectional library for the purpose of simulating different elements and materials with complex chemical compositions.

View Article and Find Full Text PDF

The purpose of this study is to verify the feasibility of applying GEANT4 (version 10.01) in neutron dose calculations in radiation protection by comparing the calculation results with MCNP5. The depth dose distributions are investigated in a homogeneous phantom, and the fluence-to-dose conversion coefficients are calculated for different organs in the Chinese hybrid male phantom for neutrons with energy ranging from 1 × 10(-9) to 10 MeV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!