Alpha2-adrenergic agonists are used to immobilize many veterinary species, but use has been infrequently linked to urine contamination of semen collected via electroejaculation. The objective of the study was to compare the α2-agonists medetomidine and dexmedetomidine on urine contamination of semen in anesthetized cheetahs (Acinonyx jubatus) during electroejaculation procedures. From 2009-2012, a retrospective medical record review revealed 21 anesthesia events in 12 adult male cheetahs. Animals were immobilized with combinations of Telazol® (2.33±0.43 mg/kg) and ketamine (2.38±1 mg/kg); Telazol (1.17±0.14 mg/kg), ketamine (1.17±0.14 mg/kg), and medetomidine (0.012±0.0017 mg/kg); or Telazol (1.59±0.1 mg/kg), ketamine (1.59±0.1 mg/kg) and dexmedetomidine (0.01±0.001 mg/kg). Semen was successfully collected in all animals; four animals anesthetized with medetomidine had urine contamination (P=0.037). Medetomidine may contribute to urine contamination; however, further investigation is needed to determine significance in cheetahs.

Download full-text PDF

Source
http://dx.doi.org/10.1638/2014-0211R2.1DOI Listing

Publication Analysis

Top Keywords

urine contamination
20
contamination semen
12
semen collected
12
mg/kg ketamine
12
collected electroejaculation
8
acinonyx jubatus
8
mg/kg
8
mg/kg telazol
8
117±014 mg/kg
8
159±01 mg/kg
8

Similar Publications

Implementation of Sensitive Method for Determination of Benzophenone and Camphor UV Filters in Human Urine.

Toxics

November 2024

Department of Food Analysis and Nutrition, Faculty of Food and Biochemical Technology, University of Chemistry and Technology, Prague, Technicka 3, 166 28 Prague, Czech Republic.

The level of the human body's burden of benzophenone and camphor ultraviolet (UV) filters can be estimated from their urinary levels. The present study describes the implementations and validation of the sensitive analytical method for the analysis of seven benzophenone and two camphor UV filters in urine. Sample preparation includes overnight enzymatic hydrolysis and ethyl acetate extraction followed by purification by dispersive solid-phase extraction using a sorbent Z-Sep.

View Article and Find Full Text PDF

Coagulase-negative (CoNS) is a rare cause of UTIs in children and is often regarded as a contaminant in urine samples. We report a case of acute focal bacterial nephritis (AFBN) and bacteremia caused by following an upper respiratory infection in a pediatric patient. The patient, a four-year-old girl, presented with fever, cough, and a runny nose two days before being referred to our hospital due to persistent fever and poor oral intake.

View Article and Find Full Text PDF

The reliable engraftment of skin grafts into areas with complex shapes can be challenging. Here, we report a case of successful fixation of a genital skin graft using negative pressure wound therapy (NPWT) with RENASYS Cotton Filler. A 44-year-old male with no relevant medical history underwent split-thickness skin grafting for a genital skin defect caused by Fournier's gangrene.

View Article and Find Full Text PDF

Aflatoxin B and fumonisin B exposure and adverse birth outcomes in HIV-infected and HIV-uninfected women from Harare, Zimbabwe.

Drug Chem Toxicol

January 2025

Immunology Unit, Department of Laboratory, Diagnostic and Investigative Sciences, Faculty of Medicine and Health Sciences, University of Zimbabwe, Harare, Zimbabwe.

Aflatoxin B (AFB1) and fumonisin B (FB1) are toxic secondary products of fungi that frequently contaminate staple crops in resource-limited settings. Antenatal AFB1 and FB1 exposure may cause adverse birth outcomes. We conducted a retrospective substudy nested in a case-control cohort of HIV-infected and HIV-uninfected women ≥20 weeks gestation from Harare, Zimbabwe.

View Article and Find Full Text PDF

Objectives: To evaluate urinalysis parameters useful for identifying mixed cultures in urine culture using an automated urinary particle analyzer to assess quality indicators (QIs) for urine sample contamination.

Methods: A retrospective observational cross-sectional study was conducted with 2,527 urine samples from patients of a quaternary hospital in Brazil. Urine samples were processed simultaneously in Sysmex UF-5000 flow cytometry analyzer (urinalysis) and MALDI-TOF (culture).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!