Aims: Implantable cardioverter-defibrillators (ICDs) have been shown to reduce mortality in patients with both ischaemic and non-ischaemic cardiomyopathy by terminating life-threatening arrhythmias. However, such arrhythmic events are unequally distributed among different patient subgroups. We aimed to evaluate predictors of appropriate ICD therapies as a step towards risk stratification in a real-world cohort.

Methods And Results: The prevalence and predictors of appropriate ICD therapies were analysed in 330 consecutive patients (mean age 65 ± 11, 81% male) with implanted ICDs due to ischaemic (n = 204) or dilated (n = 126) cardiomyopathy. During a mean follow-up of 19 ± 9 months, 1545 appropriate ICD therapies (antitachycardia pacing and shocks) were detected in 94 patients (29%). In multivariate analysis applied on the whole cohort, the presence of atrial fibrillation [AF: odds ratio (OR) = 1.906, confidence interval (CI) = 1.143-3.177, P = 0.013] and secondary prevention indication (OR = 1.963, CI = 1.123-3.432, P = 0.018) was associated with ICD therapy. The presence of cardiac resynchronization therapy (CRT) had a protective value (OR = 0.563, CI = 0.327-0.968, P = 0.038). Moreover, the predictors were different depending on the aetiology of the cardiomyopathy: in the ischaemic group, only secondary prevention indication (OR = 2.0, CI = 1.029-3.891, P = 0.041) and the presence of a biventricular system (OR = 0.359, CI = 0.163-0.794, P = 0.011) remained significant, while in the non-ischaemic group, an association with AF was observed (OR = 4.281, CI = 1.632-11.231, P = 0.003).

Conclusion: The aetiology of cardiomyopathy should be taken into consideration for the therapy of ICD patients. The protective role of CRT devices should be pointed out in ischaemic cardiomyopathy (ICM) and a more rigorous antiarrhythmic treatment should be considered for ICM patients with secondary prevention or for dilated cardiomyopathy patients with AF.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euv138DOI Listing

Publication Analysis

Top Keywords

appropriate icd
12
icd therapies
12
secondary prevention
12
patients ischaemic
8
ischaemic non-ischaemic
8
predictors appropriate
8
prevention indication
8
aetiology cardiomyopathy
8
patients
7
cardiomyopathy
6

Similar Publications

Purpose: Subclinical peroneal neuropathy without overt foot drop has been linked to increased fall risk in adults, yet remains under reported due to subtle symptoms and lack of awareness. Patients with carpal tunnel syndrome (CTS) often experience other nerve entrapments, prompting this study to evaluate CTS (a proxy for peroneal nerve entrapment) as a significant predictor of time to first fall.

Methods: Data from the Merative MarketScan Research Databases (2007-2021) were used to identify adult patients using ICD-9/10 codes.

View Article and Find Full Text PDF

Background: Desmoplakin (DSP) variants are associated with left-predominant or biventricular arrhythmogenic cardiomyopathy. Exercise promotes penetrance and sustained ventricular arrhythmias (VA) in right-sided arrhythmogenic right ventricular cardiomyopathy, but its effect is unknown in DSP variant carriers.

Objectives: To assess whether exercise is associated with clinical outcomes among individuals with a pathogenic or likely pathogenic (P/LP) DSP variant.

View Article and Find Full Text PDF

Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.

Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).

View Article and Find Full Text PDF

Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.

View Article and Find Full Text PDF

Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.

Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!