Background: Dislocation is a common complication after total hip arthroplasty (THA). Although the etiology of dislocation is multifactorial, longer-term changes in muscle such as atrophy may influence the risk of prosthetic dislocation. Biological differences in wear products generated by different bearing surfaces may influence differences in the appearance of periarticular muscle after THA; however, such bearing-associated differences to our knowledge have not been studied in vivo, and few studies have evaluated bearing-associated differences in dislocation risk.
Questions/purposes: (1) Is there a correlation between the postoperative risk of dislocation at revision and the bearing surfaces of the primary arthroplasty? (2) Is there a higher extent of fatty muscle atrophy on CT scan in hips with osteolysis (polyethylene hips) as compared with hips without osteolysis (ceramic-on-ceramic hips)? (3) Are these two abnormalities (bone osteolysis and fatty atrophy) associated with a decrease of mesenchymal stem cells (MSCs) in bone and in muscle?
Methods: We retrospectively evaluated 240 patients (240 hips) who had a THA revision (98% of which, 235 of the 240, were isolated acetabular revisions) and a normal contralateral hip. All patients had received the same implants for the primary arthroplasty (32-mm head) except for bearing surfaces (80 hips with ceramic-on-ceramic, 160 with polyethylene). No differences were noted between the groups in terms of age, sex, body mass index, proportion of patients who had a dislocation after the index arthroplasty but before the revision, and proportion of the patients with stem loosening in addition to acetabular loosening. Indications for revision generally were cup loosening. The revisions in the hips with polyethylene bearings generally had more acetabular bone loss, but the position of the center of the cup and the orientation of the cup were similar after reconstruction in the two groups. Before revision, osteolysis, muscle atrophy, and fatty degeneration were evaluated on CT scan and compared with the contralateral side. Bone muscle progenitors were evaluated by bone marrow MSCs and satellite cells for muscle. At revision, all the hips received the same implants with the same head diameter (32 mm) and a standard liner. Revisions were performed between 1995 and 2005. The followup after revision was at a mean of 14 years (range, 10-20 years) for ceramic revision and 12 years (range, 10-20 years) for polyethylene hips, and there was no differential loss to followup between the groups.
Results: More hips with polyethylene liners at the time of index arthroplasty dislocated after revision than did hips with ceramic liners (18% [29 of 160] compared with 1% [one of 80]; odds ratio, 17.5; 95% confidence interval, 2.3363-130.9100; p = 0.005). For the 80 hips with ceramic-on-ceramic, no osteolysis was detected before revision; there was no muscle fatty degeneration of the gluteus muscles on CT scan or histology. For the 160 hips with polyethylene liners, osteolytic lesions on the acetabulum and femur were observed in 100% of the hips. The increased atrophy of the gluteus muscles observed on CT scan correlated with the increase of osteolysis (r = 0.62; p = 0.012). The surgical limbs in the patients with polyethylene hips as compared with ceramic-on-ceramic hips demonstrated a greater reduction in cross-sectional area (respectively, 11.6% compared with 3%; odds ratio, 3.82; p < 0.001) and radiological density (41% [14.1/34.1] compared with 9%; odds ratio, 6.8; p = 0.006) of gluteus muscles when compared with the contralateral normal side. (41% compared with 9%; odds ratio, 6.8; p = 0.006).
Conclusions: Ceramic bearing surfaces were associated with fewer dislocations after revision than polyethylene bearing surfaces. The reasons of the lower rate of dislocation with ceramic-on-ceramic bearings may be related to observed differences in the periarticular muscles (fat atrophy or not) with the two bearing surfaces.
Level Of Evidence: Level III, therapeutic study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4626505 | PMC |
http://dx.doi.org/10.1007/s11999-015-4378-7 | DOI Listing |
Equine Vet J
January 2025
Department of Equine Clinical Science, Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Neston, UK.
Background: Trimming is critical for a functioning equine hoof. Pressure distribution provides information on loading; however, information on the effects of trimming on pressure distribution is lacking.
Objectives: To describe the pressure changes of equine fore feet following trimming.
Can Vet J
January 2025
Guardian Veterinary Centre, 5620 99th Street NW, Edmonton, Alberta T6E 1V2 (Cormillot); VCA Canada, Guardian Veterinary Centre, 5620 99th Street NW, Edmonton, Alberta T6E 1V2 (Fowler).
This case report describes metacarpophalangeal (MCP)- and metatarsophalangeal (MTP)-level amputation and reconstruction of all 4 paws of a young female domestic shorthair cat. All 4 paws, the ears, and the distal portion of the tail underwent severe frostbite injury resulting in tissue death. Following MCP and MTP amputation, weight-bearing surface reconstruction was achieved using metacarpal and metatarsal paw-pad advancement flaps.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
Synovial exudation, creeping, and lubrication failure in natural cartilage under a long-term normal loading can be counteracted by a tribo-rehydration (sliding-induced rehydration) phenomenon. Hydrogels, as porous materials, can also restore interfacial lubrication and overcome creep through this strategy. At appropriate sliding velocities, water molecules at the interface contact inlet are driven by hydrodynamic pressures into the porous network to resist creep extrusion.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
Department of Pharmacy, The First Affiliated Hospital of University of Science and Technology of China (USTC), Laboratory of Precision and Intelligent Chemistry, Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei 230026, Anhui Province, China.
Thiol-maleimide (MI) chemistry is a cornerstone of bioconjugation strategies, particularly in the development of drug delivery systems. The cyclic arginine-glycine-aspartic acid (cRGD) peptide, recognized for its ability to target the integrin αβ, is commonly employed to functionalize maleimide-bearing nanoparticles (NPs) for fabricating cRGD-functionalized nanomedicines. However, the impact of cRGD density on tumor targeting efficiency remains poorly understood.
View Article and Find Full Text PDFBiomed Mater
January 2025
School of Advanced Manufacturing, Nanchang University - Qianhu Campus, Nanchang, Jiangxi, China, Nanchang, --- Select One ---, 330031, CHINA.
The articular cartilage is characterized by its gradient hierarchical structure, which exhibits excellent lubrication and robust load-bearing properties. However, its inherent difficulty in self-repair after damage presents numerous formidable challenges for cartilage repair. Inspired by the unique structure of articular cartilage, a biomimetic bilayer hydrogel composed of PAM (polyacrylamide) and PAM/SA (sodium alginate) is prepared using a two-step in-situ swelling method.