Over the past decade, many microfluidic platforms for fluid processing have been developed in order to perform on-chip fluidic manipulations. Many of these methods, however, require expensive and bulky external supporting equipment, which are not typically applicable for microsystems requiring portability. We have developed a new type of portable contactless metal electro-osmotic micropump capable of on-chip fluid pumping, routing and metering. The pump operates using two pairs of gallium metal electrodes, which are activated using an external voltage source, and separated from a main flow channel by a thin micron-scale PDMS membrane. The thin contactless membrane allows for field penetration and electro-osmotic (EO) flow within the microchannel, but eliminates electrode damage and sample contamination commonly associated with traditional DC electro-osmotic pumps that utilize electrodes in direct contact with the working fluid. The maximum flow rates and pressures generated by the pump using DI water as a working buffer are 10 nL min(-1) and 30 Pa, respectively. With our current design, the maximum operational conductivity where fluid flow is observed is 0.1 mS cm(-1). Due to the small size and simple fabrication procedure, multiple micropump units can be integrated into a single microfluidic device for automated on-chip routing and sample metering applications. We experimentally demonstrated the ability to quantify micropump electro-osmotic flowrate and pressure as a function of applied voltage, and developed a mathematical model capable of predicting the performance of a contactless micropump for a given external load and internal hydrodynamic microchannel resistance. Finally, we showed that by activating specific pumps within a microchannel network, our micropumps are capable of routing microchannel fluid flow and generating plugs of solute.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c5lc00504c | DOI Listing |
Sensors (Basel)
December 2023
Nantes Université, CNRS, Oniris, GEPEA, UMR CNRS 6144, F-85000 La Roche-sur-Yon, France.
Microalgae provide valuable bio-components with economic and environmental benefits. The monitoring of microalgal production is mostly performed using different sensors and analytical methods that, although very powerful, are limited to qualified users. This study proposes an automated Raman spectroscopy-based sensor for the online monitoring of microalgal production.
View Article and Find Full Text PDFA reliable, but cost-effective generation of single-photon states is key for practical quantum communication systems. For real-world deployment, waveguide sources offer optimum compatibility with fiber networks and can be embedded in hybrid integrated modules. Here, we present what we believe to be the first chip-size fully integrated fiber-coupled heralded single photon source (HSPS) module based on a hybrid integration of a nonlinear lithium niobate waveguide into a polymer board.
View Article and Find Full Text PDFMolecules
June 2022
Department of Pharmacology and Physiology, Université de Montréal, Montreal, QC H3T 1J4, Canada.
Compromised activity is a common impediment for biologics requiring endosome trafficking into target cells. In cancer cells, antibody-drug conjugates (ADCs) are trapped in endosomes or subsequently pumped extracellularly, leading to a reduction in intracellular accumulation. In subsets of dendritic cells (DCs), endosome-engulfed antigens face non-specific proteolysis and collateral damage to epitope immunogenicity before proteasomal processing and subsequent surface presentation.
View Article and Find Full Text PDFNano Lett
September 2021
Key Laboratory of Optoelectronic Information and Sensing Technologies of Guangdong Higher Education Institutes, Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China.
Monolayer transition metal dichalcogenides have intrinsic spin-valley degrees of freedom, drawing broad interests due to their potential applications in information storage and processing. Here, we demonstrate the possibility of using cylindrical vector pumped beams, which are nonseparable in their polarization and spatial modes, to manipulate nonlinear valley-locked twisted-vortex emissions in monolayer tungsten disulfide (WS). The second-harmonic (SH) photons from K and K' valleys are encoded with opposite optical vortices, thus allowing the SH beams to emerge as cylindrical vector beams with doubled topological orders compared to the fundamental beams.
View Article and Find Full Text PDFGround Water
November 2021
Integrated Modeling and Prediction Division, U.S. Geological Survey, 12201 Sunrise Valley Drive, Reston, VA, USA.
The latest release of MODFLOW 6, the current core version of the MODFLOW groundwater modeling software, debuted a new package dubbed the "mover" (MVR). Using a generalized approach, MVR facilitates the transfer of water among any arbitrary combination of simulated features (i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!