A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using passive cavitation images to classify high-intensity focused ultrasound lesions. | LitMetric

AI Article Synopsis

  • Passive cavitation imaging can effectively monitor cavitation emissions but has limitations in range resolution due to the diffraction of a linear imaging array.
  • A study improved this by positioning the array perpendicular to the ultrasound direction, leading to the formation of 14 distinct lesions in bovine liver samples from ultrasound exposure.
  • Emissions at various frequencies (fundamental, harmonic, ultraharmonic) were analyzed and found to significantly predict lesion types, with the best prediction accuracy for "pre-focal" lesions.

Article Abstract

Passive cavitation imaging provides spatially resolved monitoring of cavitation emissions. However, the diffraction limit of a linear imaging array results in relatively poor range resolution. Poor range resolution has limited prior analyses of the spatial specificity and sensitivity of passive cavitation imaging in predicting thermal lesion formation. In this study, this limitation is overcome by orienting a linear array orthogonal to the high-intensity focused ultrasound propagation direction and performing passive imaging. Fourteen lesions were formed in ex vivo bovine liver samples as a result of 1.1-MHz continuous-wave ultrasound exposure. The lesions were classified as focal, "tadpole" or pre-focal based on their shape and location. Passive cavitation images were beamformed from emissions at the fundamental, harmonic, ultraharmonic and inharmonic frequencies with an established algorithm. Using the area under a receiver operating characteristic curve (AUROC), fundamental, harmonic and ultraharmonic emissions were found to be significant predictors of lesion formation for all lesion types. For both harmonic and ultraharmonic emissions, pre-focal lesions were classified most successfully (AUROC values of 0.87 and 0.88, respectively), followed by tadpole lesions (AUROC values of 0.77 and 0.64, respectively) and focal lesions (AUROC values of 0.65 and 0.60, respectively).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4526372PMC
http://dx.doi.org/10.1016/j.ultrasmedbio.2015.04.025DOI Listing

Publication Analysis

Top Keywords

passive cavitation
16
harmonic ultraharmonic
12
auroc values
12
cavitation images
8
high-intensity focused
8
focused ultrasound
8
cavitation imaging
8
poor range
8
range resolution
8
lesion formation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!