Objective: To collate all available evidence with respect to ultrasound techniques in the management of deep pelvic endometriosis (DPE) and compare the sensitivity and specificity of each to determine the most suitable site-specific method. We aim to provide clinicians with information to improve the diagnosis and management of patients with DPE.

Design: Systematic review of the literature and meta-analysis.

Setting: Not applicable.

Patient(s): None.

Interventions(s): Review of MEDLINE, EMBASE, ScienceDirect, Cochrane Library.

Main Outcome Measure(s): For each study we calculated the sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and positive/negative likelihood ratio regarding DPE sites. We then compared the specificity and sensitivity of each technique. Forest plots with the corresponding 95% confidence interval using fixed/random effects for each approach (both separately and summarized according to the weight of any single study) were used.

Result(s): A key word search strategy identified 441 manuscripts, 35 of which were eligible for the review (32 for meta-analysis). Standard transvaginal sonography (TVS) showed specificity greater than 85% for all DPE sites, despite sensitivity ranging between 50% (bladder, vaginal wall, and rectovaginal septum) and 84% (rectosigmoid). Modified techniques such as bladder site tenderness-guided TVS showed a value of 97.4% for both sensitivity and specificity. Rectal endoscopy-sonography and rectal water contrast TVS were both superior to TVS in detecting rectosigmoid endometriosis with sensitivities and specificities over 92%. Promising data were reported by using rectal water contrast TVS for rectovaginal septum disease (sensitivity, 97.1%; specificity, 99.3%).

Conclusion(s): The summary of data regarding diagnostic specificity and sensitivity of TVS in women undergoing surgery for deep endometriosis may allow us to conclude that TVS should remain the first-line method in the evaluation of patients with suspicion of DPE. When TVS is insufficient, second-line "modified-techniques" should be considered. Choosing the most effective technique is a challenge and should be based on patient history and clinical signs/symptoms.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fertnstert.2015.05.002DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
12
ultrasound techniques
8
deep pelvic
8
pelvic endometriosis
8
systematic review
8
review meta-analysis
8
dpe sites
8
specificity sensitivity
8
tvs
8
rectovaginal septum
8

Similar Publications

Objective: To conduct a meta-analysis assessing the diagnostic performance of the node reporting and data system (Node-RADS) for detecting lymph node (LN) invasion.

Method: We performed a systematic literature search of online scientific publication databases from inception up to July 31, 2024. We used the quality assessment of diagnostic accuracy studies-2 (QUADAS-2) to assess the study quality, and heterogeneity was determined by the Q-test and measured with I statistics.

View Article and Find Full Text PDF

Objectives: Artificial intelligence (AI) software including Brainomix "e-CTA" which detect large vessel occlusions (LVO) have clinical potential. We hypothesised that in real world use where prevalence is low, its clinical utility may be overstated.

Methods: In this single centre retrospective service evaluation project, data sent to Brainomix from a medium size acute National Health Service (NHS) Trust hospital between 1/3/2022-1/3/2023 was reviewed.

View Article and Find Full Text PDF

Objectives: To evaluate relationship between sFlt-1/PlGF ratio, clinical characteristics and outcomes of pre-eclampsia.

Material And Methods: Retrospective analysis of 29 pregnant women with pre-eclampsia who had measured sFlt-1/PlGF ratio was conducted using electronic medical records from Obstetrics and Perinatology ward of University Hospital in Cracow.

Results: Women median age: 33.

View Article and Find Full Text PDF

Multi-diagnostic chest-worn patch to detect obstructive sleep apnea and cardiac arrhythmias.

J Clin Sleep Med

January 2025

Division of Sleep Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.

Study Objectives: Evaluate the performance of the SANSA device to simultaneously assess obstructive sleep apnea (OSA) and cardiac arrhythmias.

Methods: Participants suspected or known to have OSA underwent polysomnography (PSG) while wearing SANSA. SANSA's algorithm was trained using 86 records and tested on 67 to evaluate training bias.

View Article and Find Full Text PDF

Objectives: Knee Osteoarthritis (OA) is one of the most frequently encountered conditions in orthopedic practice. This study aimed to validate the Knee Intake Patient Survey (KIPS), a short-form questionnaire designed to assist in the initial diagnosis and treatment stratification for knee OA.

Methods: Patient intake survey results from a single adult reconstruction clinic were retrospectively analyzed alongside clinical diagnoses and treatment recommendations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!