Unlabelled: In the construction of artificial hip joint replacements, the surface and substrate of a cross-linked polyethylene (CLPE) liner are designed to achieve high wear resistance and prevent infection by bacteria. In this study, we fabricated a highly hydrophilic and antibiofouling poly(2-methacryloyloxyethyl phosphorylcholine [MPC]) (PMPC)-graft layer on the vitamin E-blended CLPE (HD-CLPE(VE)) surface. The 100-nm-thick, smooth, and electrically neutral PMPC layer was successfully fabricated on the HD-CLPE(VE) surface using photoinduced graft polymerization. The PMPC-grafted HD-CLPE(VE) was found to prevent bacterial adherence and biofilm formation on the surface because of the formation of a highly hydrophilic polyzwitterionic layer on the surface of HD-CLPE(VE), which can serve as an extremely efficient antibiofouling layer. The number of bacterial adhered on the PMPC-grafted HD-CLPE(VE) surface was reduced by 100-fold or more by PMPC grafting, regardless of the biofilm-production characteristics of the strains. In contrast, vitamin E blending did not affect bacterial adhesion. Moreover, the number of planktonic bacteria did not differ significantly, regardless of PMPC grafting and vitamin E blending. In conclusion, the PMPC-grafted HD-CLPE(VE) provided bacteriostatic effects associated with smooth, highly hydrophilic surfaces with a neutral electrostatic charge owing to the zwitterionic structure of the MPC unit. Thus, this modification may prove useful for the production of artificial hip joint replacement materials.

Statement Of Significance: Our preliminary in vitro findings suggest that improved bacteriostatic performance of the HD-CLPE(VE) surface in orthopedic implants is possible via PMPC grafting. The results also indicate that surface modifications affect the anti-infection properties of the orthopedic implants and demonstrate that the application of a PMPC-grafted HD-CLPE(VE) surface may be a promising approach to extend the longevity and clinical outcomes of total hip arthroplasty. Further research is needed to evaluate the resistance to infection of PMPC-grafted HD-CLPE(VE) in terms of the varieties of biofilm formation tests including fluid flow conditions and animal experiments, which may offer useful clues to the possible performance of these materials in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2015.05.034DOI Listing

Publication Analysis

Top Keywords

hd-clpeve surface
20
pmpc-grafted hd-clpeve
20
biofilm formation
12
highly hydrophilic
12
pmpc grafting
12
surface
10
hd-clpeve
9
bacterial adhesion
8
vitamin e-blended
8
cross-linked polyethylene
8

Similar Publications

The emergence of self-propelling magnetic nanobots represents a significant advancement in the field of drug delivery. These magneto-nanobots offer precise control over drug targeting and possess the capability to navigate deep into tumor tissues, thereby addressing multiple challenges associated with conventional cancer therapies. Here, Fe-GSH-Protein-Dox, a novel self-propelling magnetic nanobot conjugated with a biocompatible protein surface and loaded with doxorubicin for the treatment of triple-negative breast cancer (TNBC), is reported.

View Article and Find Full Text PDF

During maritime operations, extreme events such as explosions, grounding, and seal failures can cause water ingress into lubricant compartments, forming oil-water emulsions that significantly affect the lubrication performance of ship stern bearings. Existing studies mainly focus on low water content, with limited exploration of the impact of high water content on lubrication performance. To address this gap, viscosity measurements of oil-water mixtures were conducted, and an emulsification viscosity equation applicable to varying water contents was derived.

View Article and Find Full Text PDF

The incident angle of seismic waves influences the dynamic response of rock slopes. However, the relationship between the back-slope effect in strong earthquake areas and the incident angle has not been well-explained. Based on the equivalent nodal force method and the viscoelastic artificial boundary theory, the oblique incidence of seismic P-wave and SV-wave are carried out in FLAC3D software.

View Article and Find Full Text PDF

Autonomous microgrids (ATMG), with green power sources, like solar and wind, require an efficient control scheme to secure frequency stability. The weather and locationally dependent behavior of the green power sources impact the system frequency imperfectly. This paper develops an intelligent, i.

View Article and Find Full Text PDF

This study aimed to evaluate the histological success of pulpotomy in primary molars using white mineral trioxide aggregate (WMTA) mixed with 2.25% sodium hypochlorite (NaOCl) gel and to evaluate in vitro its physical and chemical properties. The study had a clinical stage and an in-vitro stage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!